LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2012 >> SX4 Base >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Keyless Start System >> Diagnostic Information and Procedures >> Keyless Start Control Module Power and Ground Circuit Check >> Troubleshooting
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Keyless Start Control Module Power and Ground Circuit Check: Troubleshooting

TROUBLESHOOTING CHART

Step Action YES NO
Fuse check 
  1. Turn ignition switch to OFF position.
  2. Check circuit fuse and main fuse for condition.

Are fuses in good condition? 
Go to Step 2. Replace fuse(s) and check for short.
Power supply circuit check 
  1. Disconnect connector from keyless start control module.
  2. Check for proper connection to "Power source", "ACC signal" and "IG ON signal" terminal of keyless start control module connector.
  3. If OK, measure voltage between following terminals.
    • "Power source" terminal of keyless start control module connector and vehicle body ground with ignition switch is at OFF position
    • "ACC signal" terminal of keyless start control module connector and vehicle body ground with ignition switch is at ACC position
    • "IG ON signal" terminal of keyless start control module connector and vehicle body ground with ignition switch is at ON position

Is each terminal voltage is 10 - 14 V? 
Go to Step 3. Repair defective power supply circuit.
Ground circuit check 
  1. Check for proper connection to "Ground" terminal of keyless start control module connector.
  2. If OK, measure resistance between "Ground" terminal of keyless start control module connector and vehicle body ground.

Is resistance 1 Ω or less? 
Power and ground circuit is in good condition. Repair ground circuit.