IMT Valve Actuator Inspection
Reference: "IMT VALVE ACTUATOR REMOVAL AND INSTALLATION
"
CAUTION:
The IMT valve actuator may be damaged if battery voltage is applied to it for longer than 10 seconds. Limit the time of battery voltage application to the IMT valve actuator to no more than 10 seconds.
- Connect battery positive (+) and negative (-) terminals to IMT valve actuator (1) as shown in
chart below. If it does not operate as specified direction, replace IMT valve actuator.
DIAGNOSTIC INFORMATION AND PROCEDURES REFERENCE CHART
| Rotative direction |
a |
b |
| clockwise |
+ |
- |
| counterclockwise |
- |
+ |
Courtesy of SUZUKI OF AMERICA CORP.