CKP Sensor Inspection
Reference: CKP SENSOR REMOVAL AND INSTALLATION
- Check the following points:
- Check that O-ring (1) is free from damage.
- Check that end face of sensor and signal plate tooth are free from any metal particles and damage.
- Check CKP sensor as follows.
If faulty condition is found, replace CKP sensor, see CKP SENSOR REMOVAL AND INSTALLATION .
- Connect battery (1) and ohmmeter (3) to CKP sensor as shown in figure.
- Check that CKP sensor resistance varies as specified below by bringing magnetic substance (iron) to CKP sensor.NOTE: Be sure to keep approximately 1 mm (0.03 in) gap "a" between magnetic substance (iron) and end face of CKP sensor.
CKP sensor resistance
Resistance varies between less than 220 Ω (ON) and infinity (OFF)