General Cooling System Service - General Information: Testing: Thermostat
- Remove and inspect thermostat for corrosion and proper seating of valve. If okay, suspend thermostat and thermometer in a 50/50 mixture of coolant and water. See Fig 1. DO NOT allow thermostat or thermometer to touch bottom or container. Heat water until thermostat begins to open.
- Read temperature on thermometer. This is the initial opening temperature and should be within specification. Continue heating water until thermostat is fully open and note temperature. This is the fully open temperature. If either reading is not to specification, replace thermostat.