All Models
- Check all hoses and connections. With engine coolant below 45°F (8°C), remove air by-pass hose from air cleaner housing.
- Start engine. Air should discharge from air by-pass hose. As engine warms up, air by-pass should stop. Leave hose disconnected and proceed with system check.