System Check: Tercel
- Warm up engine to normal operating temperature. Set engine speed at 2000 RPM. Check that air is discharged intermittently from air by-pass hose. Return engine speed to idle and check that air discharge stops.
- Disconnect vacuum hose from ASV and check that air discharges from air by-pass valve. Reconnect hose. Air should stop discharging within 2-6 seconds.
- Disconnect vacuum hose from air by-pass valve and check that air does not discharge from air by-pass valve. Reconnect hose. Air should momentarily discharge from air by-pass hose.
- Pinch hose at vacuum switch with fingers and gradually increase engine speed. Check that intermittent air stops discharging from air by-pass hose at 1600 RPM. Release hose.
- Return engine speed to idle. At service connector, located on left fender panel near ignition coil, connect a wire from "TWC" terminal to "E" terminal. Air should discharge from air by-pass hose. Disconnect wire.
- Disconnect hose located between check valve and EGR valve at check valve. Check that air is discharging from check valve.
- Stop engine and reconnect all hoses. If system performed correctly, testing is complete. If not, check individual components as necessary.