BVSV 2
- Drain coolant from radiator into container. Remove BVSV 2 and immerse in coolant. Check that air flows from pipe "J" to pipe "L" when temperature is below 113°F (45°C).
- Heat coolant to above 147°F (64°C). Check that air flows from pipe "J" to pipe "K".