Airflow Meter Testing

Turn ignition off. Disconnect wiring connector from airflow meter. Using an ohmmeter, measure resistance between each terminal. If resistance values do not meet specifications shown in chart, replace airflow meter.

AIRFLOW METER RESISTANCE SPECIFICATIONS

Terminals Condition Ohms
E1 - Fc Flap Closed (1) Infinity
" Flap Open Zero
E2 - THA 4°F (-20°C) 10,000-20,000
" 32°F (0°C) 4000-7000
" 68°F (20°C) 2000-3000
" 104°F (40°C) 900-1300
" 140°F (60°C) 400-700
E2 - Vb N/A 200-400
E2 - Vc N/A 200-400
E2 - Vs Flap Closed 20-400
" Flap Open (1) 20-1000
(1) Resistance changes with flap position.