Actuator & WASTEGATE
Disconnect actuator hose. Using a pressure gauge, apply 8.2-8.7 psi (.58-.61 kg/cm2 ) of pressure to actuator hose and check that rod moves .0098" (.25 mm) or more. If less, replace turbocharger assembly.
CAUTION:
Never apply more than 11.4 psi (.8 kg/cm2
) of pressure to the actuator.