2WD (4A-GE)
- Measure pick-up coil resistance between terminals "G(+)" and "G(-)", and between "NE(+)" and "NE(-)". Resistance should be 140-180 ohms when checked at room temperature.
- If resistance is not within specification, replace distributor. See PICK-UP COIL RESISTANCE table. If resistance is within specification, proceed to PICK-UP COIL AIR GAP CHECK .
PICK-UP COIL RESISTANCE
| Application | Ohms |
|---|---|
| All Models | 140-180 |