LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 1990 >> Land Cruiser >> Repair and Diagnosis >> Quick Lookups >> Technical Bulletins >> Tech Tips >> Memory Modules >> Blower Motor CONTINUTES To Operate When Car Is Off (TOY0283AP)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Blower Motor CONTINUTES To Operate When Car Is Off (TOY0283AP)

Publication date: 1998-03-01
Reference number: TOY0283AP

BLOWER MOTOR CONTINUTES TO OPERATE WHEN CAR IS OFF

BLOWER MOTOR CONTINUTES TO OPERATE WHEN CAR IS OFF

TECHNICAL INFORMATION TIP

Reference Number(s): TOY0283AP, Date of Issue:  March 1998
COPYRIGHT: © 2018 Toyota, USA License Agreement TMS1002

DEFOGGER & BLOWER MOTOR CONTINUE TO RUN WHILE KEY IS OFF

YEAR(S): 1990

MANUFACTURER: Toyota

MODEL(S): Landcruiser

DATE OF ISSUE: March 1998

ISSUE & TIP

I recently repaired a 1990 Toyota Landcruiser with the following problem: If the ignition key was turned OFF while the rear window defogger was ON, the defogger and blower motor would continue to run, discharging the battery.

The cause: A loss of ground to the rear hatch (the upper portion with the window in it. Voltage feeds back through the rear wiper circuit, through the wiper and gauge fuses, and keeps the ignition relay activated.

The solution: Add a ground wire between the upper corner of the hatch and this chassis.

Courtesy of Import Service Magazine

with thanks to:

Thomas Brandolini

Haverhill Tune-up

East Kingston, New Hampshire

REFERENCE NUMBER

TOY0283AP

NOTE: This information has been obtained from sources generally believed to be reliable. Use your own judgment before relying on this data. Neither the suppliers of these Technical Information Tips, nor lemon-25 Repair Information Company, LLC, guarantees or assumes responsibility for data accuracy or completeness, nor is liability assumed by the suppliers of these Technical Information Tips or lemon-25 Repair Information Company, LLC, for any claims or damages resulting from the use of this information.