AIRFLOW METER RESISTANCE SPECIFICATIONS
| Application & Terminals |
Ohms |
| E2-Vc |
200-400 |
| E1-Fc |
| Measuring Plate Fully Closed |
No Continuity |
| Measuring Plate Open |
0 |
| E2-Vs |
| Fully Closed |
200-600 |
| Fully Open |
20-1200 |
| E2-THA |
| -4°F (-20°C) |
10,000-20,000 |
| 32°F (0°C) |
4000-7000 |
| 68°F (20°C) |
2000-3000 |
| 104°F (40°C) |
900-1300 |
| 140°F (60°C) |
400-700 |
COLD START INJECTOR RESISTANCE SPECIFICATIONS
| Application |
Ohms |
| Cressida |
2.0-4.0 |
COLD START INJECTOR TIME SWITCH RESISTANCE SPECIFICATIONS
| Terminals |
Temperature: °F (°C) |
Ohms |
| STA-STJ |
Less Than 59 (15) |
25-45 |
| " |
Greater Than 86 (30) |
65-85 |
| STA-Ground |
N/A |
25-85 |
NOTE:
For coolant temperature sensor specifications, see Fig 1.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002 EGR GAS TEMP SENSOR SPECIFICATIONS
| Temperature: °F (°C) |
Ohms |
| 122 (50) |
69-89 |
| 212 (100) |
12-14 |
| 302 (150) |
3-4 |
FUEL INJECTOR RESISTANCE SPECIFICATIONS
| Application |
Ohms |
| All Others |
Approx. 13.8 |
ISC VALVE RESISTANCE SPECIFICATIONS
| Application |
Ohms |
| Cressida |
10-30 |
OXYGEN SENSOR HEATER RESISTANCE SPECIFICATIONS
| Condition |
Ohms |
| 68°F (20°C) |
5.1-6.3 |
TPS RESISTANCE SPECIFICATIONS
| Terminal |
Clearance: In. (mm) |
Ohms |
| VTA & E2 |
0 (0) |
300-6300 |
| " |
Fully Open |
3500-10,300 |
| IDL & E2 |
.020 (.51) |
2300 Or Less |
| " |
.035 (.58) |
No Continuity |
| VC & E2 |
Fully Open |
4250-8250 |