Ignitor Power Transistor Check
- Turn ignition off. Unplug ignition module 4-pin connector. Disconnect each ignition coil pack 2-pin connector. Turn ignition on. Connect ohmmeter between terminal No. 2 of third ignition coil and ground. See Fig 1
- Using a 3-volt dry cell battery, apply 3 volts to terminal No. 2 of 4-pin connector. With 3 volts applied, ensure ohmmeter indicates momentary continuity. Connect ohmmeter between terminal No. 2 of first ignition coil and ground.
- Apply 3 volts to terminal No. 4 of 4-pin connector. With 3 volts still applied to terminal No. 4, also apply 3 volts to terminal No. 2. Ensure ohmmeter indicates momentary continuity. See Fig 1t ohmmeter between terminal No. 2 of second ignition coil and ground.
- Apply 3 volts to terminal No. 3 of 4-pin connector. With 3 volts still applied to terminal No. 3, also apply 3 volts to terminal No. 2. Ensure ohmmeter indicates momentary continuity. See Fig 1e ignitor if tests are not as specified.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002