Sensor Operating Specifications
NOTE:
Perform all voltage tests with a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance, unless stated otherwise in test procedure.
NOTE:
Air temperature sensor is mounted on intake air box. For sensor specifications, see Fig 1.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002 COLD START INJECTOR RESISTANCE SPECIFICATIONS
| Application |
Ohms |
| Tercel |
2.0-4.0 |
COLD START INJECTOR TIME SWITCH RESISTANCE SPECIFICATIONS
| Terminals |
Temperature: °F (°C) |
Ohms |
| STA-STJ |
Below 86 (30) |
20-40 |
| " |
Above 104 (40) |
40-60 |
| STA-Ground |
N/A |
20-80 |
NOTE:
For coolant temperature sensor specifications, see Fig 2.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002 EGR GAS TEMPERATURE SENSOR SPECIFICATIONS
| Temperature: °F (°C) |
Ohms |
| 122 (50) |
69.40-88.50 |
| 212 (100) |
11.89-14.37 |
| 302 (150) |
2.79-3.59 |
FUEL INJECTOR RESISTANCE SPECIFICATIONS
| Application |
Ohms |
| Tercel |
Approx. 13.8 |
TPS RESISTANCE SPECIFICATIONS
| Terminal |
Clearance: In. (mm) |
Ohms |
| VTA & E2 |
0 (0) |
200-800 |
| " |
Fully Open |
3300-10,000 |
| IDL & E2 |
.020 (.50) |
2300 Or Less |
| " |
.028 (.70) |
Infinity |
| VC & E2 |
N/A |
3000-7000 |
VACUUM SENSOR SPECIFICATIONS
| Vacuum: In. Hg |
Voltage Drop |
| 3.94 |
.3-.5 |
| 7.87 |
.7-.9 |
| 11.81 |
1.1-1.3 |
| 15.75 |
1.5-1.7 |
| 19.69 |
1.9-2.1 |