Code 31, 32/Test No. 6 - Airflow Meter Signal
CODE 31, 32/TEST NO. 6-AIRFLOW METER SIGNAL TROUBLE
| Terminals | Trouble | Condition | STD Voltage |
|---|---|---|---|
| VC - E2 | No Voltage | All | 4 - 6V |
| VS - E2 | " | Ignition Switch ON Measuring Plate CLOSED | 3.7 - 4.3V |
| VS - E2 | " | Ignition Switch ON Measuring Plate OPEN | 0.2 - 0.5V |
| VS - E2 | " | Idling | 2.3 - 2.8V |
| VS - E2 | " | 3000 RPM | 1.0 - 2.0V |