Throttle Position Sensor
NOTE:
For terminal identification and testing procedures, see SYSTEM/COMPONENT TESTS
article.
TPS RESISTANCE SPECIFICATIONS
| Application Type | Clearance In. (mm) | Terminals Tested | Ohmmeter Reading | ||
|---|---|---|---|---|---|
| 2.4L | 0 (0) | VTA & E2 | 470-6100 | ||
| " | .022 (.56) | IDL & E2 | 2300 Or Less | ||
| " | .034 (.86) | IDL & E2 | No Continuity | ||
| " | Fully Open | VTA & E2 | 3100-12,100 | ||
| " | " | VCC & E2 | 3900-9000 | ||
| 3.0L (1) | 0 (0) | VTA & E2 | 470-6100 | ||
| " | .020 (.51) | IDL & E2 | 2300 Or Less | ||
| " | .031 (.79) | IDL & E2 | No Continuity | ||
| " | Fully Open | VTA & E2 | 3100-12,100 | ||
| " | " | VC & E2 | 3900-9000 | ||
|
|||||