Distributor Sensors
DISTRIBUTOR PICK-UP COIL AIR GAP
| Application | In. (mm) |
|---|---|
| Corolla | .008-.016 (.20-.40) |
DISTRIBUTOR PICK-UP COIL RESISTANCE
| Application | (1) Pick-Up Coil Terminals | Ohms | ||||||
|---|---|---|---|---|---|---|---|---|
| Cold (2) | G+ & G- | 185-275 | ||||||
| Cold (2) | NE+ & NE- | 370-550 | ||||||
| Hot (3) | G+ & G- | 240-325 | ||||||
| Hot (3) | NE+ & NE- | 475-650 | ||||||
|
||||||||