Sub-Oxygen Sensor Heater
Sub-oxygen sensor heater may be used on various models. See OXYGEN SENSOR APPLICATION table. Using ohmmeter, measure resistance between sensor terminals +B and HT. For terminal identification, see the SYSTEM/COMPONENT TESTS article. Replace sub-oxygen sensor if resistance is not 11-16 ohms at 68°F (20°C).