2-Door Models
- Connect 3 "D" cell batteries in series, creating 4.5 volts. Connect VGS terminal of deceleration sensor to positive (+) side of batteries. See Fig 1. Connect GGND terminal to negative (-) side of batteries.
- Measure voltage between terminal GL1 and ground, and between terminal GL2 and ground at deceleration sensor. Ensure sensor is within specifications. See DECELERATION SENSOR SPECIFICATIONS . If sensor is not within specification, replace sensor.
DECELERATION SENSOR SPECIFICATIONS
| Terminal |
Position |
Voltage |
| GL1 |
Horizontal |
2.3 |
| GL1 |
Leaning Forward |
0-2.3 |
| GL1 |
Leaning Rearward |
2.3-4.5 |
| GL2 |
Horizontal |
2.3 |
| GL2 |
Leaning Forward |
2.3-4.5 |
| GL2 |
Leaning Rearward |
0-2.3 |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002