Power Window Control System: Inspection
- INSPECT POWER WINDOW REGULATOR SWITCH ASSY
- Check continuity.
- Check the continuity between the terminals when battery voltage is applied to terminals 1 and 8.
Standard:
POWER WINDOW REGULATOR SWITCH OPERATIONSwitch operation Measurement condition Specified condition UP Battery positive - Terminal 8 Battery negative - Terminal 1 Continuity between terminals 3 - 7 Continuity between terminals 1 - 6 DOWN Battery positive - Terminal 8 Battery negative - Terminal 1 Continuity between terminals 1 - 3 Continuity between terminals 6 - 7 If the continuity is not as specified, replace the switch.
- Check continuity.