Mode 6 - 2004 TOYOTA: Echo
O2S HEATER
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.000076 (A) | Maximum HO2S heater current (bank 1 sensor 1) | Malfunction criterion |
| 1 | $02 | Multiply by 0.000076 (A) | Maximum HO2S heater current (bank 1 sensor 2) | Malfunction criterion |
TID $08: Thermostat
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.625 and subtract 40 °C | ECT sensor output when estimated ECT reaches malfunction criterion | Malfunction criterion |
TID $01: Catalyst- Using Front HO2S and Rear HO2S
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiply by 0.0078 (no dimension) | Catalyst deterioration level bank 1: Determined by waveform of front HO2S and rear HO2S | Malfunction criterion |
TID $02: EVAP - Vacuum Monitor (1NZ-FE)
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.0916 (mmHg) | Test value of EVAP VSV: Determined by fuel tank pressure change during vacuum introduction | Malfunction criterion |
| 1 | $02 | Multiply by 0.0458 and subtract 2.93 (mmHg) | Test value of CCV: Determined by fuel tank pressure change at switching over CCV | Malfunction criterion |
| 0 | $03 | Multiply by 0.0458 (mmHg) | Test value of 0.04 inch leak: Determined by fuel tank pressure change | Malfunction criterion |
| 0 | $04 | Multiply by 0.0458 (mmHg) | Test value of 0.02 inch leak: Determined by fuel tank pressure change | Malfunction criterion |