Mode 6 - 2004 TOYOTA: MR2
TID $04: HO2S Heater
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.000076 (A) | Maximum HO2S heater current (bank 1 sensor 1) | Malfunction criterion |
| 1 | $02 | Multiply by 0.000076 (A) | Maximum HO2S heater current (bank 1 sensor 2) | Malfunction criterion |
| 1 | $10 | Multiply by 0.000076 (A) | Maximum HO2S heater current (bank 2 sensor 1) | Malfunction criterion |
TID $08: THERMOSTAT
| TLT CID | Unit Conversion | Description of Test Value | Description of Test Limit | |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.625 and subtract 40 (°C) | ECT sensor output when estimated ECT reaches malfunction criterion | Malfunction criterion |
O2S TEST RESULT
| TEST DATA | Description of TEST DATA | Conversion Factor | Unit | Standard Value of TEST LIMIT |
|---|---|---|---|---|
| Time $31 | Time to change from Lean (less than or equal to 0.35 V) to Rich (greater than or equal to 0.45 V) | N/A | Second | Between 0 and 1 seconds |
| Time $32 | Time to change from Rich (less than or equal to 0.45 V) to Rich (greater than or equal to 0.435V) | N/A | Second | Between 0 and 1 seconds |
Rear O2S (Bank 1 Sensor 2 and Bank 2 sensor 2)
| TEST DATA | Description of TEST DATA | Conversion Factor Unit | Standard Value of TEST LIMIT |
|---|---|---|---|
| Time $81 | Percentage in monitoring time where oxygen sensor voltage is less than 0.05 V | Multiply 0.3906 | Between 0 and 60 % |
| Time $84 | Percentage in monitoring time where oxygen sensor voltage is 0.70 V or more | Multiply 0.3906 | Between 20 and 100 % |
| Time $85 | Maximum Rich (greater than or equal to 0.45 V) time | Multiply 0.2621 Second | Between 20 and 66.8 seconds |
TID $01: Catalyst-Using Front HO2S and Rear HO2
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 0 01 | Multiply by 0.0078 | no dimension) | Catalyst deterioration level bank 1: Determined by waveform of front HO2S and rear HO2S | Malfunction criterion |
TID $02: EVAP - Vacuum Monitor
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | 01 | Multiply by 0.0916 (mmHg) | Test value of EVAP VSV: Determined by fuel tank pressure change during vacuum introduction | Malfunction criterion |
| 1 | 02 | Multiply by 0.0458 and subtract 2.93 (mmHg) | Test value of bypass VSV (pressure switching valve) and CCV: Determined by fuel tank pressure change at switching over bypass VSV and CCV | Malfunction criterion |
| 0 | 03 | Multiply by 0.0458 (mmHg) | Test value of 0.04 inch leak: Determined by fuel tank pressure change | Malfunction criterion |
| 0 | 04 | Multiply by 0.0458 (mmHg) | Test value of 0.02 inch leak: Determined by fuel tank pressure change | Malfunction criterion |