Mode 6 - 2004 TOYOTA: PRIUS
HO2S Heater Bank 1 Sensor 2
| MID | TID | Scaling | Description of Test Value |
|---|---|---|---|
| $42 | $90 | Multiply by 0.001 (A) | Maximum sensor heater current |
Thermostat
| MID | TID | Scaling | Description of Test Value |
|---|---|---|---|
| $E1 | $E8 | Multiply by 0.1 (°C) | ECT sensor output when estimated ECT reaches malfunction criterion |
Catalyst Bank 1
| MID | TID | Scaling | Description of Test Value |
|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 (no dimension) | Oxygen storage capacity |
EVAP - BLADDER TANK SYSTEM
| MID | TID | Scaling | Description of Test Value |
|---|---|---|---|
| $3D | $D6 | Multiply by 0.01 (%/%) | Test value of bladder tank leak: Determined by fuel vapor concentration in outer fuel tank |
A/F Sensor Bank 1
| MID | TID | Scaling | Description of Test Value |
|---|---|---|---|
| $01 | $8E | Multiply by 0.0003 (no dimension) | Response rate deterioration level |