Service Data: 2ZZ-GE:
Service Data Emission Control System 2ZZ-GE
| Oxyzen sensor | ||
| Resistance | HT - +B | 11 to 16 Ω |
| VSV for Pressure switching valve | ||
| Resistance | at 20°C (68°F) | 37 to 44 Ω |
| Vacuum switching valve No.1 | ||
| Resistance | at 20°C (68°F) | 27 to 33 Ω |
| Vacuum switching valve assy No. 1 | ||
| Resistance | at 20°C (68°F) | 25 to 30 Ω |
| Pressure sensor | ||
| Voltage | AIP - E2 | 1.0 to 2.2 V |
| Air pump relay | ||
| Continuity | 1 - 2 | Continuity |
| 3 - 4 | No continuity | |
| 3 - 4 (Apply battery voltage to terminal 1 and 2) | Continuity | |
| Vacuum switching valve assy | ||
| Resistance | at 20°C (68°F) | 33 to 39 Ω |