Repair Instruction: Initialization
NOTE:
When disconnect the negative (-) battery terminal, initialize the following systems after the terminal is reconnected.
INITIALIZATION
| System Name | See Step No. |
|---|---|
| Power Window Control System | 1 |
NOTE:
- Resetting the power window regulator motor (initializing the pulse sensor) is necessary if: 1) the battery terminal cable is disconnected; 2) the power window regulator master switch assembly, wire harness, power window regulator switch, power window regulator assembly and power window regulator motor are replaced or removed/installed; or 3) the POWER fuse, FR Door fuse, GAUGE fuse and ECU-IG fuses are replaced. If resetting is not performed, the master switch assembly will not be able to operate the AUTO operation function, jam protection function and remote operation function.
- Whenever disconnecting the battery terminal cable, reset all the other systems besides the power window control system.
- Change the power mode to ON (IG) by pushing the power switch.
- Open the power window halfway by pressing the power window switch.
- Fully pull up on the switch until the power window is fully closed and continue to hold the switch for at least 1 second.
- Check that the AUTO UP/DOWN function operates normally.
If the AUTO UP/DOWN function operates normally, reset operations have been completed. If abnormal, follow steps ( e) fto ( g) below.
- Disconnect the negative battery terminal cable for 10 seconds.
- Connect the battery terminal cable.
- Perform the above steps ( a) b cto ( d) again.