Service Data
Emission Control Service Data
| VSV for canister closed valve | ||
| Resistance | at 20°C (68°F) | 25 to 30 Ω |
| at 100°C (212°F) | 32 to 42 Ω | |
| VSV for EVAP | ||
| Resistance | at 20°C (68°F) | 26 to 30 Ω |
| Air fuel ratio sensor | ||
| Resistance | 1 (TH) - 2 (+B) | 0.8 - 1.4 Ω at 20°C (68°F) |
| 1 (TH) - 2 (+B) | 1.8 - 3.2 Ω at 800°C (1,472°F) | |
| 1 (HT) - 4 (E1) | No continuity | |
| Heated oxygen sensor (Bank 1 oxygen sensor No. 2) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| 1 (HT) - 4 (E1) | No continuity | |
| Heated oxygen sensor (Bank 2 oxygen sensor No. 2) | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| 1 (HT) - 4 (E1) | No continuity |