VSV For Pressure Switching Valve: Inspection
- REMOVE VSV
- INSPECT VSV
- Inspect the VSV for open circuit.
Using an ohmmeter, check that there is continuity between the terminals.
Resistance: 30 - 36 Ω at 20°C (68°F)
If there is no continuity, replace the VSV.
- Inspect the VSV for ground.
Using an ohmmeter, check that there is no continuity between each terminal and the body.
If there is no continuity, replace the VSV.
- Inspect the VSV operation
- Check that air does not flow from ports E to F.
- Apply battery positive voltage to the terminals.
- Check that air flows from ports E to F.
If the operation is not as specified, replace the VSV.
- Inspect the VSV for open circuit.
- REINSTALL VSV