Typical Malfunction Thresholds
TYPICAL MALFUNCTION THRESHOLDS
| Following conditions are met: (during idling after driving for more than 6.2 mph (10 km/h) per cycle) |
A, B and C |
| A. Either of following conditions is met: | 1 or 2 |
| 1. Deviation of engine speed (when shift position N or A/C ON) |
Less than -100 rpm, or more than 200 rpm |
| 2. Deviation of engine speed (when shift position D or A/C OFF) |
Less than -100 rpm, or more than 150 rpm |
| B. IAC flow rate (learned value) | 0.6 L/sec or less or 4.5 L/sec or more |
| C. Number of detection | 5 times/trip |