Service Data
SERVICE DATA REFERENCE
| Camshaft timing oil control valve - Standard resistance |
Terminals 1 - 2 at 20°C (68°F) | - | 6.9 to 7.9 Ω |
| Camshaft position sensor - Standard resistance |
Terminals 1 - 2 Cold | The terms "Cold" and "Hot" refer to the temperature of the sensor. "Cold" means approximately -10 to 50°C (14 to 122°F). "Hot" means approximately 50 to 100°C (122 to 212°F). | 1, 630 to 2, 740 Ω |
| Terminals 1 - 2 Hot | 2, 065 to 3, 225 Ω | ||
| Crankshaft position sensor - Standard resistance |
Terminals 1 - 2 Cold | The terms "Cold" and "Hot" refer to the temperature of the sensor. "Cold" means approximately -10 to 50°C (14 to 122°F). "Hot" means approximately 50 to 100°C (122 to 212°F). | 985 to 1, 600 Ω |
| Terminals 1 - 2 Hot | 1, 265 to 1, 890 Ω | ||
| Engine coolant temperature sensor - Standard resistance |
Terminals 1 - 2 at 20°C (68°F) | - | 2.32 to 2.59 Ω |
| Terminals 1 - 2 at 80°C (176°F) | - | 0.310 to 0.326 Ω | |
| Throttle body (throttle control motor) - Standard resistance |
Terminals 1 - 2 at 25 °C (77°F) | - | 50 MΩ or more |
| Throttle body (throttle position sensor) - Standard resistance |
Terminals 1 - 4 at 25 °C (77°F) | - | 1.2 to 3.5 kΩ |
| Knock sensor - Standard resistance |
Terminals 1 - 2 at 20°C (68°F) | - | 120 to 280 kΩ |
| EFI relay - Standard resistance |
Terminals 3I-5 - 3I-8 | - | 10 kΩ or higher |
| Terminals 3I-5 - 3I-8 | When battery voltage is applied to terminals 3I-6 and 3I-7) | Below 1 Ω | |
| Circuit opening relay - Standard resistance |
Terminals 3G-5 - 3G-8 | - | 10 kΩ or higher |
| Terminals 3G-5 - 3G-8 | When battery voltage is applied to terminals 3G-6 and 3G-7) | Below 1 Ω |