LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2006 >> Prius >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission >> Electronic Shift Lever System >> Data List / Active Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Data List / Active Test

  1. READ DATA LIST 

    HINT:

    Using the intelligent tester's DATA LIST allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the DATA LIST early in troubleshooting is one way to save time.

    1. Connect the intelligent tester (with CAN VIM) to the DLC3.
    2. Turn the power switch ON (IG) and press the intelligent tester main switch on.
    3. Read the DATA LIST by following the directions on the tester screen.

      Transmission control ECU 

      DATA LIST / ACTIVE TEST DESCRIPTION

      Item Measurement Item / Range (Display) Normal Condition Diagnostic Note
      SHFT POS P Shift position display (P) / ON or OFF ON: Parking lock is in P position
      OFF: Parking lock is in non-P position
      -
      SHFT POS N-P Shift position display (not P) / ON or OFF ON: Parking lock is in non-P position
      OFF: Parking lock is in P position
      -
      MAS CAUTION Master caution display / DISP or NONDISP DISP: Malfunction occurs in this system
      NONDISP: Malfunction does not occur in this system
      -
      PSW INDICATOR PSW indicator mode / OFF, ON, FAST, or SLOW OFF: Parking lock is in non-P position
      ON: Parking lock is in P position
      FAST: Actuator takes long time to switch between the P position and non-P position
      SLOW: Malfunction occurs in this system
      -
      U VOL VAL U phase voltage value / min: 0 V, max: 20 V Actual U phase voltage 9 to 14 V -
      V VOL VAL V phase voltage value / min: 0 V, max: 20 V Actual V phase voltage 9 to 14 V -
      W VOL VAL W phase voltage value / min: 0 V, max: 20 V Actual W phase voltage 9 to 14 V -
      BATT VOL VAL BATT voltage value / min: 0 V, max: 20 V Actual power supply voltage 9 to 14 V -
      IG (+B) VOL VAL IG (+B) voltage value / min: 0 V, max: 20 V Actual power supply voltage 9 to 14 V -
      P SPLY OFF SIG Power supply off preparation request signal / ON or OFF ON: Power is turned off by power source control ECU after receiving power switch OFF signal
      OFF: Any other condition
      -
      LRN LOCK POS Completion of learning lock position / OK or NG OK: Lock position learning is complete
      NG: Lock position learning is not complete
      -
      LRN UNLOCK POS Completion of learning unlock position / OK or NG OK: Unlock position learning is complete
      NG: Unlock position learning is not complete
      -
      TRIP CNTR Number of trip counter after learning / min: 0, max: 65535 Actual number of trip counter Reset the trip counter after 1,000 times
      MTR MAIN RELAY Main relay for motor drive / ON or OFF ON: Motor drive main relay on
      OFF: Motor drive main relay off
      -
      ELCTRCL KEY SIG Signal of electrical key condition / ON or OFF ON: Electrical key is recognized
      OFF: Electrical key is not recognized
      -
      #CODE Number of diagnosis code / min: 0, max: 255 Actual number of diagnosis code -
      CURRENT U U phase current-carrying status / ON or OFF ON: U phase current flows
      OFF: U phase current does not flow
      -
      CURRENT V V phase current-carrying status / ON or OFF ON: V phase current flows
      OFF: V phase current does not flow
      -
      CURRENT W W phase current-carrying status / ON or OFF ON: W phase current flows
      OFF: W phase current does not flow
      -
      U VOL U phase voltage status / ON or OFF ON: U phase voltage is 6 V or more
      OFF: U phase voltage is less than 6 V
      -
      V VOL V phase voltage status / ON or OFF ON: V phase voltage is 6 V or more
      OFF: V phase voltage is less than 6 V
      -
      W VOL W phase voltage status / ON or OFF ON: W phase voltage is 6 V or more
      OFF: W phase voltage is less than 6 V
      -
      BATT VOL BATT voltage status / ON or OFF ON: BATT voltage is more than 10 V
      OFF: BATT voltage is 10 V or less
      -
      IG VOL IG (+B) phase voltage status / ON or OFF ON: +B voltage is more than 10 V
      OFF: +B voltage is 10 V or less
      -
      ACC SIG ACC condition signal / ON or OFF ON: ACC condition signal is normal
      OFF: ACC condition signal is interrupted
      -
      INIT CNTRL Initial drive control completed / OK or NG OK: Initial drive control is complete
      NG: Initial drive control is not complete
      -
      DTCT LOCK POS Completion of detecting lock position / OK or NG OK: Detection of lock position is complete
      NG: Detection of lock position is not complete
      -
      DTCT UNLOCK POS Completion of detecting unlock position / OK or NG OK: Detection of unlock position is complete
      NG: Detection of unlock position is not complete
      -
      SHFT RANGE P/Not P movable shift range / SET or UNSET SET: P/Not P movable shift range is set
      UNSET: P/Not P movable shift range is unset
      -
      MAIN RELAY Main relay / NORMAL or ABNOML NORMAL: Main relay is normal
      ABNOML: Main relay is fault
      -
      VHCL COND Vehicle condition / STOP or MOVE STOP: Vehicle is stopped
      MOVE: Vehicle is running
      -
      ECU TYPE Type of ECU / min: 0, max: 65535 Actual type of ECU -