Data List/Active Test
- DATA LIST
HINT:
By reading the DATA LIST displayed on an intelligent tester, you can check values including those of the switches, sensors, and actuators, without removing any parts. Reading the DATA LIST as the first step of troubleshooting is one method of shortening diagnostic time.
NOTE: In DATA LIST TABLE , the values listed under Normal Condition are for reference only. Do not depend solely on these values when determining whether or not a part is faulty.- Warm up the engine.
- Turn the ignition switch OFF.
- Connect an intelligent tester to the DLC3.
- Turn the ignition switch ON.
- Turn the tester ON.
- Select the following menu items: DIAGNOSIS/ENHANCED OBD II / DATA LIST.
- Check the values by referring to DATA LIST TABLE .
DATA LIST TABLEIntelligent Tester Display Measurement Item: Range (Display) Normal Condition (1) Diagnostic Note INJECTOR Injection period of No. 1 cylinder: Min.: 0 ms, Max.: 32.64 ms 1.6 to 2.4 ms: Idling - IGN ADVANCE Ignition timing advance for No. 1 cylinder/
Min.: -64° , Max.: 63.5°BTDC 7 to 24°: Idling - CALC LOAD Calculated load by ECM:
Min.: 0%, Max.: 100%- 11.4 to 16.4%: Idling
- 13.1 to 18.9%: Running without load (2,500 rpm)
- VEHICLE LOAD Vehicle load:
Min.: 0%, Max.: 25,700%Actual vehicle load - MAF Air flow rate from MAF meter:
Min.: 0 g/sec, Max.: 655.35 g/sec3.2 to 4.7 g/sec: Idling
13.1 to 18.9 g/sec: 2,500 rpmIf value approximately 0.0 g/sec: - Mass air flow meter power source circuit open
- VG circuit open or short If value 160.0 g/sec or more:
- E2G circuit open
ENGINE SPD Engine speed:
Min.: 0 rpm, Max.: 16,383.75 rpm650 to 750 rpm: Idling - VEHICLE SPD Vehicle speed:
Min.: 0 km/h, Max.: 255 km/hActual vehicle speed Speed indicated on speedometer COOLANT TEMP Engine coolant temperature:
Min.: -40°C, Max.: 140°C80 to 100°C (176 to 212°F): After warming up - If value -40°C (-40°F): sensor circuit open
- If value 140°C (284°F) or more: sensor circuit shorted
INTAKE AIR Intake air temperature:
Min.: -40°C, Max.: 140°CEquivalent to ambient air temperature - If value -40°C (-40°F): sensor circuit open
- If value 140°C (284°F) or more: sensor circuit shorted
AIR-FUEL RATIO Air-fuel ratio:
Min.: 0, Max.: 1.9990.8 to 1.2: During idling - PURGE DENSITY Learning value of purge density/
Min.: -50, Max.: 350-40 to 0%: Idling Service data EVAP PURGE FLOW Purge flow:
Min.: 0%, Max.: 102.4%0 to 100%: Idling - EVAP PURGE VSV EVAP (Purge) VSV control duty:
Min.: 0%, Max.: 100%0 to 100%: During idling Order signal from ECM VAPOR PRES PUMP Vapor pressure:
Min.: 33.853 kPa, Max.: 125.596 kPaApproximately 100 kPa: Ignition switch ON EVAP system pressure monitored by canister pressure sensor VAPOR PRES CALC Vapor pressure: (calculated)
Min.: -5.632 kPa, Max.: 7,153,264 kPaApproximately 100 kPa: Ignition switch ON EVAP system pressure monitored by canister pressure sensor KNOCK CRRT VAL Correction learning value of knocking:
Min.: -64° CA, Max.: 1,984°CA0 to 22°CA: Driving, 44 mph (70 km/h) Service data KNOCK FB VAL Feedback value of knocking:
Min.: -64°CA, Max.: 1,984°CA-22 to 0°CA Driving, 44 mph (70 km/h) Service data ACCEL POS #1 Absolute Accelerator Pedal Position (APP) No. 1:
Min.: 0%, Max.: 100%10 to 22%: Accelerator pedal released
54 to 86%: Accelerator pedal fully depressed- ACCEL POS #2 Absolute APP No. 2:
Min.: 0%, Max.: 100%12 to 42%: Accelerator pedal released
66 to 98%: Accelerator pedal fully depressed- ACCEL POS #1 APP sensor No. 1 voltage:
Min.: 0 V, Max.: 5 V0.5 to 1.1 V: Accelerator pedal released.
2.6 to 4.5t V: Accelerator pedal fully depressed.- ACCEL POS #2 APP sensor No. 2 voltage:
Min.: 0 V, Max.: 5 V1.2 to 2.0 V: Accelerator pedal released.
3.4 to 5.0 V: Accelerator pedal fully depressed.- ACCEL IDL POS Whether or not accelerator pedal position sensor detecting idle: ON or OFF ON: Idling - THRTL LEARN VAL Throttle valve fully closed (learned value):
Min.: 0 V, Max.: 5 V0.4 to 0.8 V - ACCEL SSR #1 AD Accelerator fully closed value No.1 (AD):
Min.: 0, Max.: 4.9804 V- ETCS service data ACCEL LRN VAL #1 Accelerator fully closed learning value No. 1:
Min.: 0, Max.: 124.512- ETCS service data ACCEL LRN VAL #2 Accelerator fully closed learning value No. 2:
Min.: 0, Max.: 124.512- ETCS service data FAIL #1 Whether or not fail safe function executed:
ON or OFFON: ETCS has failed - FAIL #2 Whether or not fail safe function executed:
ON or OFFON: ETCS has failed - ST1 Starter signal:
ON or OFFON: Cranking - SYS GUARD JUDGE System guard:
ON or OFF:- ETCS service data OPN MALFUNCTION Open side malfunction:
ON or OFF- ETCS service data THROTTLE POS Absolute throttle position sensor:
Min.: 0%, Max.: 100%- 10 to 24%: Throttle fully closed
- 64 to 96%: Throttle fully open
Read value with intrusive operation (active test) THROTTL IDL POS Whether or not throttle position sensor detecting idle:
ON or OFFON: Idling - THRTL REQ POS Throttle requirement position:
Min.: 0 V, Max.: 5 V0.5 to 1.0 V: Idling - THROTTLE POS Throttle sensor positioning;
Min.: 0%, Max.: 100%0 to 10%: Idling Calculated value based on VTA1 THROTTLE POS #2 Throttle sensor positioning #2:
Min.: 0%, Max.: 100%- Calculated value based on VTA2 THROTTLE POS #1 Throttle position No. 1:
Min.: 0 V, Max.: 5 V- 0.5 to 1.2 V: Throttle fully closed
- 3.2 to 4.8 V: Throttle fully opened
- THROTTLE POS #2 Throttle position No. 2:
Min.: 0 V, Max.: 5 V- 2.0 to 2.9 V: Throttle fully closed
- 4.6 to 5.0 V: Throttle fully open
Read value with intrusive operation (active test) THRTL COMND VAL Throttle position command value:
Min.: 0 V, Max.: 4.98 V0.5 to 4.8 V ETCS service data THROTTLE SSR #1 Throttle sensor opener position No. 1:
Min.: 0 V, Max.: 4.9804 V0.6 to 1.0 V ETCS service data THROTTLE SSR #2 Throttle sensor opener position No. 2:
Min.: 0 V, Max.: 4.9804 V2.0 to 2.6 V ETCS service data THRTL SSR #1 AD Throttle sensor opener position No.1 (AD):
Min.: 0 V, Max.: 4.9804 V0.6 to 0.9 V ETCS service data THROTTLE MOT Whether or not throttle motor control permitted:
ON or OFFON: Idling Read value with ignition switch ON (Do not start engine) THROTTLE MOT Throttle motor current:
Min.: 0 A, Max.: 80 A0 to 3.0 A: Idling - THROTTLE MOT Throttle motor:
Min.: 0%, Max.: 100%0.5 to 40%: Idling - THRTL MOT (OPN) Throttle motor duty ratio (open):
Min.: 0%, Max.: 100%- ETCS service data THRTL MOT (CLS) Throttle motor duty ratio (close):
Min.: 0%, Max.: 100%- ETCS service data O2S B1 S2 Heated oxygen sensor output voltage for bank 1 sensor 2:
Min.: 0 V, Max.: 1.275 V0.1 to 0.9 V: Driving 44 mph (70 km/h) Performing INJ VOL or A/F CONTROL function of ACTIVE TEST enables technician to check voltage output of sensor O2S B2 S2 Heated oxygen sensor output voltage for bank 2 sensor 2:
Min.: 0 V, Max.: 1.275 V0.1 to 0.9 V: Driving 44 mph (70 km/h) Performing INJ VOL or A/F CONTROL function of ACTIVE TEST enables technician to check voltage output of sensor AFS B1 S1 A/F sensor output voltage for bank 1 sensor 1:
Min.: 0 V, Max.: 7.999 V2.8 to 3.8 V: Idling Performing INJ VOL or A/F CONTROL function of ACTIVE TEST enables technician to check voltage output of sensor AFS B2 S1 A/F sensor output voltage for bank 2 sensor 1:
Min.: 0 V, Max.: 7.999 V2.8 to 3.8 V: Idling Performing INJ VOL or A/F CONTROL function of ACTIVE TEST enables technician to check voltage output of sensor AFS B2 S1 A/F sensor output current for bank 2 sensor 1:
Min.: -128 mA, Max.: 127.99 mA- Performing INJ VOL or A/F CONTROL function of ACTIVE TEST enables technician to check current output of sensor TOTAL FT #1 Total fuel trim of bank 1 Average value for fuel trim system of bank 1:
Min.: -0.5, Max.: 0.496-0.2 to 0.2: Idling - TOTAL FT #2 Total fuel trim of bank 2 Average value for fuel trim system of bank 2:
Min.: -0.5, Max.: 0.496-0.2 to 0.2: Idling - SHORT FT #1 Short-term fuel trim of bank 1:
Min.: -100%, Max.: 99.2%0 +- 20% Short-term fuel compensation used to maintain air-fuel ratio at stoichiometric air-fuel ratio LONG FT #1 Long-term fuel trim of bank 1:
Min.: -100%, Max.: 99.2%0 +- 20% Overall fuel compensation carried out in long-term to compensate continual deviation of short-term fuel trim from central value SHORT FT #2 Short-term fuel trim of bank 2:
Min.: -100%, Max.: 99.2%0 +- 20% Short-term fuel compensation used to maintain air-fuel ratio at stoichiometric air-fuel ratio LONG FT #2 Long-term fuel trim of bank 2:
Min.: -100%, Max.: 99.2%0 +- 20% Overall fuel compensation carried out in long-term to compensate continual deviation of short-term fuel trim from central value FUEL SYS #1 Fuel system status (Bank 1):
OL or CL or OL DRIVE or OL FAULT or CL FAULTCL: Idling after warming up - OL (Open Loop): Has not yet satisfied conditions to go closed loop
- CL (Closed Loop): Using heated oxygen sensor as feedback for fuel control
- OL DRIVE: Open loop due to driving conditions (fuel enrichment)
- OL FAULT: Open loop due to detected system fault
- CL FAULT: Closed loop but heated oxygen sensor, which used for fuel control, malfunctioning
FUEL SYS #2 Fuel system status (Bank 2):
OL or CL or OL DRIVE or OL FAULT or CL FAULTCL: Idling after warming up - OL (Open Loop): Has not yet satisfied conditions to go closed loop
- CL (Closed Loop): Using heated oxygen sensor as feedback for fuel control.
- OL DRIVE: Open loop due to driving conditions (fuel enrichment)
- OL FAULT: Open loop due to detected system fault
- CL FAULT: Closed loop but heated oxygen sensor, which used for fuel control, malfunctioning
O2FT B1 S2 Short-term fuel trim associated with bank 1 sensor 2:
Min.: -100%, Max.: 99.2%- - O2FT B2 S2 Short-term fuel trim associated with bank 2 sensor 2:
Min.: -100%, Max.: 99.2% :- - AF FT B1 S1 Short-term fuel trim associated with bank 1 sensor 1:
Min.: 0, Max.: 1.999- Value less than 1 (0.000 to 0.999) = Lean
- Stoichiometric air-fuel ratio=1
- Value greater than 1 (1.001 to 1.999) = RICH
- AFS B1 S1 A/F sensor output current for bank 1 sensor 1:
Min.: -128 mA, Max.: 127.99 mA- Performing INJ VOL or A/F CONTROL function of ACTIVE TEST enables technician to check current output of sensor AF FT B2 S1 Short-term fuel trim associated with bank 2 sensor 1:
Min.: 0, Max.: 1.999- Value less than 1 (0.000 to 0.999) = Lean
- Stoichiometric air-fuel ratio=1
- Value greater than 1 (1.001 to 1.999) = RICH
- CAT TEMP B1S1 Catalyst temperature (Bank 1, Sensor 1):
Min.: -40, Max.: 6,513.5°C- - CAT TEMP B2S1 Catalyst temperature (Bank 2, Sensor 1):
Min.: -40, Max.: 6,513.5°C- - CAT TEMP B1S2 Catalyst temperature (Bank 1, Sensor 2):
Min.: -40, Max.: 6,513.5°C- - CAT TEMP B2S2 Catalyst temperature (Bank 2, Sensor 2):
Min.: -40, Max.: 6,513.5°C- - S O2S B1 S2 Sub heated oxygen sensor impedance (Bank 1, Sensor 2):
Min.: 0 Ω, Max.: 21247.68 Ω- - S O2S B2 S2 Sub heated oxygen sensor impedance (Bank 2, Sensor 2):
Min.: 0 Ω, Max.: 21247.68 Ω- - INI COOL TEMP Initial engine coolant temperature:
Min.: -40°C, Max.: 120°CCoolant temperature when engine started Service data INI INTAKE TEMP Initial intake air temperature:
Min.: -40°C, Max.: 120°CIntake air temperature when engine started Service data INJ VOL Injection volume (cylinder 1):
Min.: 0 ml, Max.: 2.048 ml0 to 0.5 ml Quantity of fuel injection volume for 10 times STARTER SIG Starter signal:
ON or OFFON: Cranking - PS SW Power steering signal:
ON or OFFON: Power steering operation - PS SIGNAL Power steering signal (history):
ON or OFFON: When steering wheel first turned after battery terminals connected This signal status usually ON until battery terminals disconnected CTPSW Closed throttle position switch: ON or OFF ON: Throttle fully closed
OFF: Throttle open- A/C SIGNAL A/C signal:
ON or OFFON: A/C ON - PNP SW [NSW] PNP switch status:
ON or OFFON: P or N position - ELECT LOAD SIG Electrical load signal:
ON or OFFON: Headlights or defogger turned ON - STOP LIGHT SW Stop light switch:
ON or OFFON: brake pedal depressed - +BM Whether or not electric throttle control system power inputted:
ON or OFFON: Ignition switch ON and system normal - +BM VOLTAGE +BM voltage:
Min.: 0, Max.: 19.9218211 to 14 (V): Ignition switch ON and system normal ETCS service data BATTERY VOLTAGE Battery voltage:
Min.: 0 V, Max.: 65.535 V11 to 14 V: Idling - ACTUATOR POWER Actuator power supply:
ON or OFFON: Idling ETCS service data ATM PRESSURE Atmospheric pressure:
Min.: 0 kPa, Max.: 255 kPaEquivalent to atmospheric pressure (absolute pressure) - FUEL PMP SP CTL Fuel pump speed control status:
ON/H or OFF/LIdling: ON - ACIS VSV ACIS VSV:
ON or OFF- ON: Open
OFF: ClosedACT VSV A/C cut status for Active Test:
ON or OFF- Active Test support data VVT CTRL B2 VVT control (bank 2) status:
ON or OFF- Active Test support data EVAP (Purge) VSV VSV status for EVAP control:
ON or OFF- Active Test support data FUEL PUMP/SPD Fuel pump/status:
ON or OFF- Active Test support data VVT CTRL B1 VVT control (bank 1) status:
ON or OFF- Active Test support data VACUUM PUMP Key-off EVAP system pump status:
ON or OFF- Active Test support data EVAP VENT VAL Key-off EVAP system vent valve status:
ON or OFF- Active Test support data TC/TE1 TC and CG (TE1) terminal of DLC3:
ON or OFF- - ENG SPEED #1 Engine RPM for cylinder 1:
Min.: 0 rpm, Max.: 25,600 rpm- Output only when FUEL CUT #1 is performed using ACTIVE TEST ENG SPEED #2 Engine RPM for cylinder 2:
Min.: 0 rpm, Max.: 25,600 rpm- Output only when FUEL CUT #2 is performed using ACTIVE TEST ENG SPEED #3 Engine RPM for cylinder 3:
Min.: 0 rpm, Max.: 25,600 rpm- Output only when FUEL CUT #3 is performed using ACTIVE TEST ENG SPEED #4 Engine RPM for cylinder 4:
Min.: 0 rpm, Max.: 25,600 rpm- Output only when FUEL CUT #4 is performed using ACTIVE TEST ENG SPEED #5 Engine RPM for cylinder 5:
Min.: 0 rpm, Max.: 25,600 rpm- Output only when FUEL CUT #5 is performed using ACTIVE TEST ENG SPEED #6 Engine RPM for cylinder 6:
Min.: 0 rpm, Max.: 25,600 rpm- Output only when FUEL CUT #6 is performed using ACTIVE TEST ENG SPEED ALL Engine RPM for all cylinders:
Min.: 0 rpm, Max.: 25,600 rpm- Output only when ACTIVE TEST is performed VVTL AIM ANGL #1 (2) VVT aim angle (bank 1):
Min.: 0%, Max.: 100%0 to 100% VVT duty signal value during intrusive operation VVT CHNG ANGL#1 (2) VVT change angle:
Min.: 0°FR, Max.: 60°FR0 to 56°FR Displacement angle during intrusive operation VVT OCV DUTY B1 (2) VVT OCV operation duty:
Min.: 0%, Max.: 100%0 to 100% Requested duty value for intrusive operation VVTL AIM ANGL #2 (2) VVT aim angle (bank 2):
Min.: 0%, Max.: 100%0 to 100% VVT duty signal value during intrusive operation VVT CHNG ANGL #2 (2) VVT change angle (bank 2):
Min.: 0°FR, Max.: 60°FR0 to 56°FR Displacement angle during intrusive operation VVT OCV DUTY B2 (2) VVT OCV (bank 2) operation duty:
Min.: 0%, Max.: 100%0 to 100% Requested duty value for intrusive operation FCIDL Fuel cut idle:
ON or OFFON: Fuel cut operation FC IDL = "ON" when throttle valve fully closed and engine speed over 3,500 rpm FC TAU Fuel cut TAU: Fuel cut during very light load:
ON or OFFON: Fuel cut operating Fuel cut being performed under very light load to prevent engine combustion from becoming incomplete IGNITION Ignition counter:
Min.: 0, Max.: 6000 to 600 - CYL #1 Misfire ratio of cylinder 1:
Min.: 0, Max.: 2550 This item displayed in only idling CYL #2 Misfire ratio of cylinder 2:
Min.: 0, Max.: 2550 This item displayed in only idling CYL #3 Misfire ratio of cylinder 3:
Min.: 0, Max.: 2550 This item displayed in only idling CYL #4 Misfire ratio of cylinder 4:
Min.: 0, Max.: 2550 This item displayed in only idling CYL #5 Misfire ratio of cylinder 5:
Min.: 0, Max.: 2550 This item displayed in only idling CYL #6 Misfire ratio of cylinder 6:
Min.: 0, Max.: 2550 This item displayed in only idling CYL ALL All cylinders misfire rate:
Min.: 0, Max.: 2550 to 35 - MISFIRE RPM Engine RPM for first misfire range:
Min.: 0 rpm, Max.: 6,375 rpm0 rpm: Misfire 0 - MISFIRE LOAD Engine load for first misfire range:
Min.: 0 g/rev, Max.: 3.98 g/rev0 g/rev: Misfire 0 - MISFIRE MARGIN Margin to detect engine misfire:
Min.: -100%, Max.: 99.22%-100 to 99.2% Misfire detecting margin #CODES Number of detected DTCs:
Min.: 0, Max.: 2550: No DTC detected - CHECK MODE Check mode:
ON or OFFON: Check mode ON See CHECK MODE PROCEDURE SPD TEST Check mode result for vehicle speed sensor:
COMPL or INCMPL- - MISFIRE TEST Check mode result for misfire monitor:
COMPL or INCMPL- - OXS2 TEST Check mode result for HO2 sensor (bank 2):
COMPL or INCMPL- - OXS1 TEST Check mode result for HO2 sensor (bank 1):
COMPL or INCMPL- - A/F SSR TEST B2 Check mode result for air-fuel ratio sensor (bank 2) :
COMPL or INCMPL- - A/F SSR TEST B1 Check mode result for air-fuel ratio sensor (bank 1):
COMPL or INCMPL- - MIL MIL status:
ON or OFFON: MIL ON - MIL ON RUN DIST MIL ON RUN Distance:
Min.: 0 km, Max.: 65,535 kmDrive distance after DTC detected - MIL ON RUN TIME Running time from MIL ON:
Min.: 0 min., Max.: 65,535 min.Equivalent to running time after MIL ON - ENG RUN TIME Engine run time:
Min.: 0 s., Max.: 65,535 s.Time after engine start Service data TIME DTC CLEAR Time after DTC cleared:
Min.: 0 min., Max.: 65,535 min.Equivalent to time after DTCs erased - DIST DTC CLEAR Distance after DTC cleared:
Min.: 0 km, Max.: 65,535 kmEquivalent to drive distance after DTCs erased - WU CYC DTC CLEAR Number of warm-up cycles after DTC cleared:
Min.: 0, Max.: 255- - OBD CERT OBD requirement OBD2 - #CARB CODES Number of emission related DTCs 0: No emission related DTC detected - COMP MON Comprehensive component monitor:
NOT AVL or AVAIL- - FUEL MON Fuel system monitor:
NOT AVL or AVAIL- - MISFIRE MON Misfire monitor:
NOT AVL or AVAIL- - EGR MON EGR monitor:
NOT AVL or AVAIL- - EGR MON EGR monitor:
COMPL or INCMPL- - O2S (A/FS) HTR O2S (A/FS) heater monitor:
NOT AVL or AVAIL- - O2S (A/FS) HTR O2S (A/FS) heater monitor:
COMPL or INCMPL- - O2S (A/FS) MON O2S (A/FS) monitor:
NOT AVL or AVAIL- - O2S (A/FS) MON O2S (A/FS) monitor:
COMPL or INCMPL- - A/C MON A/C monitor:
NOT AVL or AVAIL- - A/C MON A/C monitor:
COMPL or INCMPL- - 2nd AIR MON 2nd air monitor:
NOT AVL or AVAIL- - 2nd AIR MON 2nd air monitor:
COMPL or INCMPL- - EVAP MON EVAP monitor:
NOT AVL or AVAIL- - EVAP MON EVAP monitor:
COMPL or INCMPL- - HTD CAT MON Heated catalyst monitor:
NOT AVL or AVAIL- - HTD CAT MON Heated catalyst monitor:
COMPL or INCMPL- - CAT MON Catalyst monitor:
NOT AVL or AVAIL- - CAT MON Catalyst monitor:
COMPL or INCMPL- - CCM ENA Comprehensive component monitor:
UNABLE or ENABLE- - CCM CMPL Comprehensive component monitor:
COMPL or INCMPL- - FUEL ENA Fuel system monitor:
UNABLE or ENABLE- - FUEL CMPL Fuel system monitor:
COMPL or INCMPL- - MISFIRE ENA Misfire monitor:
UNABLE or ENABLE- - MISFIRE CMPL Misfire monitor:
COMPL or INCMPL- - EGR ENA EGR monitor:
UNABLE or ENABLE- - EGR CMPL EGR monitor:
COMPL or INCMPL- - HTR ENA O2S (A/FS) heater monitor:
UNABLE or ENABLE- - HTR CMPL O2S (A/FS) heater monitor:
COMPL or INCMPL- - O2S (A/FS) ENA O2S (A/FS) monitor:
UNABLE or ENABLE- - O2S (A/FS) CMPL O2S (A/FS) monitor:
COMPL or INCMPL- - ACRF ENA A/C monitor:
UNABLE or ENABLE- - ACRF CMPL A/C monitor:
COMPL or INCMPL- - AIR ENA 2nd air monitor:
UNABLE or ENABLE- - AIR CMPL 2nd air monitor:
COMPL or INCMPL- - EVAP ENA EVAP monitor:
UNABLE or ENABLE- - EVAP CMPL EVAP monitor:
COMPL or INCMPL- - HCAT ENA Heated catalyst monitor:
UNABLE or ENABLE- - HCAT CMPL Heated catalyst monitor:
COMPL or INCMPL- - CAT ENA Catalyst monitor:
UNABLE or ENABLE- - CAT CMPL Catalyst monitor:
COMPL or INCMPL- - MODEL CODE Identifying model code GSJ1## - ENGINE TYPE Identifying engine type 1GRFE - CYLINDER NUMBER Identifying cylinder number:
Min.: 0, Max.: 2556 - TRANSMISSION Identifying transmission type:
MT or 5ATMT: Manual transmission
5AT: Automatic transmission- DESTINATION Identifying destination A (America) - MODEL YEAR Identifying model year:
Min.: 1900, Max.: 2155200# - SYSTEM Identifying engine system GASLIN (gasoline engine) - (1) If no idling conditions are specified, the transmission gear selector lever should be in the N or P position, and the A/C switch and all accessory switches should be OFF. (2) DATA LIST values are only displayed when performing the following ACTIVE TESTs: VVT B1 or VVT B2. For other ACTIVE TESTs, the DATA LIST value will be 0. - ACTIVE TEST
HINT:
Performing an ACTIVE TEST enables components including the relays, VSV (Vacuum Switching Valve), and actuators, to be operated without removing any parts. The ACTIVE TEST can be performed with an intelligent tester. Performing an ACTIVE TEST as the first step of troubleshooting is one method of shortening diagnostic time.
DATA LIST can be displayed during ACTIVE TESTs.
- Connect an intelligent tester to the DLC3.
- Turn the ignition switch ON.
- Turn the tester ON.
- Select the following menu items: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST.
- Perform the ACTIVE TEST by referring to ACTIVE TEST REFERENCE TABLE .
ACTIVE TEST REFERENCE TABLEIntelligent Tester Displays Test Details Control Ranges Diagnostic Notes INJ VOL Change injection volume Between -12.5% and 24.8% - All injectors tested at same time
- Perform test at less than 3,000 rpm
- Injection volume can be changed in 0.1% graduations within control range
A/F CONTROL Change injection volume Lower by 12.5% or increase by 25% - Perform test at less than 3,000 rpm
- A/F CONTROL enables checking and graphing of A/F (Air Fuel Ratio) sensor and Heated Oxygen (HO2) sensor voltage outputs
- To conduct test, select following menu items: ACTIVE TEST/A/F CONTROL/USER DATA/ AFS B1S1 and O2S B1S2, and press YES and ENTER followed by F4
FUEL PMP SP CTL Fuel pump speed control ON (low speed)/ OFF (high speed) - INTAKE CTL VSV1 ACIS VSV ON/OFF - EVAP VSV (ALONE) Activate EVAP VSV control ON/OFF - A/C CUT SIG Control A/C cut signal ON/OFF - FUEL PUMP/SPD Activate fuel pump (C/OPN Relay) ON/OFF - TC/TE1 Turn on and off TG and CG (TE1) connection ON/OFF - ON: TC and CG (TE1) connected
- OFF: TC and CG (TE1) disconnected
FCIDL PROHBT Prohibit idling fuel cut control ON/OFF - ETCS OPEN SLOW Throttle actuator ON: throttle valve opens slowly Test possible when following conditions met: - Ignition switch ON
- Engine does not start
- Fully depressing accelerator pedal (APP: 58 degrees or more)
ETCS CLOSE SLOW Throttle actuator ON: throttle valve closes slowly ETCS OPEN FAST Throttle actuator ON: throttle valve opens fast ETCS CLOSE FAST Throttle actuator ON: throttle valve closes fast VVT B1 Control the VVT (bank 1) -128 to 127%
This value added to present OCV control duty
100%: Maximum advance
-100%: Maximum retard- Engine stall or rough idle when VVT actuator operated by 100%
- Test possible during engine idling
VVT CTRL B1 Turn on and off OCV (Oil Control Valve) ON/OFF - Engine stalls or idles roughly when OCV turned ON
- Normal engine running or idling when OCV off
VVT B2 Control the VVT (bank 2) -128 to 127%
This value added to present OCV control duty
100%: Maximum advance
-100%: Maximum retard- Engine stall or rough idle when VVT actuator operated by 100 %
- Test possible during engine idling
VVT CTRL B2 Turn on and off OCV (Oil Control Valve) ON/OFF - Engine stalls or idles roughly when OCV turned ON
- Normal engine running or idling when OCV off
VACUUM PUMP Leak detection pump ON/OFF - VENT VALVE Vent valve ON/OFF - FUEL CUT #1 Cylinder #1 injector fuel cut ON/OFF Test possible during vehicle stopping and engine idling FUEL CUT #2 Cylinder #2 injector fuel cut ON/OFF FUEL CUT #3 Cylinder #3 injector fuel cut ON/OFF FUEL CUT #4 Cylinder #4 injector fuel cut ON/OFF FUEL CUT #5 Cylinder #5 injector fuel cut ON/OFF FUEL CUT #6 Cylinder #6 injector fuel cut ON/OFF FUEL CUT ALL All cylinder injectors fuel cut ON/OFF COMPRESS CHECKS All cylinder injectors fuel cut and ignition stop ON/OFF * HINT:
*: When cranking the engine, each cylinder measures the engine rpm.In this ACTIVE TEST, the fuel and ignition of all cylinders are cut, and cranking occurs for approximately 10 seconds. Then, each cylinder measures the engine rpm. If a cylinder's engine rpm is higher than the others, that cylinder's compression pressure is compared to the others, and is determined whether it is low or not.
- Warm up the engine.
- Turn the ignition switch off.
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch ON and turn the intelligent tester on.
- Select the following menu items: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / COMPRESS CHECK.
HINT:
If the results are not displayed normally, select the display items from the DATA LIST before performing the ACTIVE TEST. Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / USER DATA / ENG SPEED #1, ENG SPEED #2, ENG SPEED #3, ENG SPEED #4, ENG SPEED #5, ENG SPEED #6 (Press the YES button to change the ENG SPEED #1 to #6) and then press the ENTER button.
- While the engine is not running, press the RIGHT or LEFT button to change the COMPRESS CHECK to ON.
HINT:
After performing the above procedure, the ACTIVE TEST'S COMPRESS CHECK will start. Fuel injection for all cylinders is prohibited, and each cylinder's engine rpm measurement will enter standby mode.
- Fully open the throttle.
- Crank the engine for about 10 seconds.
- Monitor the engine speed (ENG SPEED #1 to #6) displayed on the tester.
HINT:
At first, the tester's display will show each cylinder's engine rpm measurement to be extremely high. After approximately 10 seconds of engine cranking, each cylinder's engine rpm measurement will change to the actual engine rpm.
NOTE:- After the ACTIVE TEST'S COMPRESS CHECK is turned ON, it will automatically turn off after 255 seconds.
- When the COMPRESS CHECK test is OFF and the engine is cranked, the engine will start.
- If the COMPRESS CHECK test needs to be performed after it is turned ON and performed once, press EXIT to return to the ACTIVE TEST menu screen. Then perform the COMPRESS CHECK test again.
- Use a fully-charged battery.
- SYSTEM CHECK
HINT:
Performing a SYSTEM CHECK enables the system, which consists of multiple actuators, to be operated without removing any parts; In addition, it can show whether or not any DTCs ape set, and can detect potential malfunctions in the system. The SYSTEM CHECK can be performed With an intelligent tester.
- Connect an intelligent tester to the DLC3.
- Turn the ignition switch ON.
- Turn the tester ON.
- Select the following menu items: DIAGNOSIS / ENHANCED OBD II / SYSTEM CHECK.
- Perform the SYSTEM CHECK by referring to TEST DETAILS AND DIAGNOSTIC NOTES TABLE .
TEST DETAILS AND DIAGNOSTIC NOTES TABLEIntelligent tester Displays Test Details Recommended Fuel Temperatures Diagnostic Notes EVAP SYS CHECK (AUTO OPERATION) Perform 5 steps in order to operate EVAP key-off monitor automatically 35°C (95°F) or less - If no DTCs in PENDING CODE after performing this test, system functioning normally
- Refer to EVAP INSPECTION PROCEDURE
EVAP SYS CHECK (MANUAL OPERATION) Perform 5 steps in order to operate EVAP key-off monitor manually 35°C (95°F) or less - Used to detect malfunctioning parts
- Refer to EVAP INSPECTION PROCEDURE