Data List / Active Test
- DATA LIST
HINT:
By reading the DATA LIST displayed on an intelligent tester or OBD II scan tool, you can check values, including those of the switches, sensors, and actuators, without removing any parts. Reading the DATA LIST as the first step of troubleshooting is one method of shortening diagnostic time.
NOTE: In the table below, the values listed under Normal Conditions are for reference only. Do not depend solely on these values when determining whether or not a part is faulty.- Warm up the engine.
- Turn the ignition switch to OFF.
- Connect an intelligent tester or OBD II scan tool to the DLC3.
- Turn the ignition switch to ON.
- Turn the tester or scan tool ON.
- If using an intelligent tester, select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST.
- If using an OBD II scan tool, refer to the instruction manual.
- Check the values by referring to the table below.TESTER DISPLAY AND DIAGNOSTIC NOTES
Tester Display Measurement Item/Range Normal Condition Diagnostic Notes INJECTOR Injection period of No. 1 cylinder: Min.: 0 ms, Max.: 32.6 ms 1.1 to 2.5 ms: Idling - IGN ADVANCE Ignition timing advance for No. 1 cylinder: Min.: -64 deg., Max.: 63.5 deg. BTDC 8 to 20 deg: Idling - CALC LOAD Calculated load by ECM: Min.: 0 %, Max.: 100% - 11.3 to 20.0%: Idling
- 11.5 to 17.9%: Running without load (2,500 rpm)
- MAF Air flow rate from Mass Air Flow (MAF) meter: Min.: 0 g/sec, Max.: 665.35 g/sec - 1.4 to 2.3 g/sec for Manual Transaxle (M/T): Idling
- 1.4 to 2.3 g/sec for Automatic Transaxle (A/T): Idling
- 5.4 to 7.9 g/sec: Running without load (2,500 rpm)
If value is approximately 0.0 g/ sec: - MAF meter power source circuit open
- VG circuit open or shorted
If value is 271.0 g/sec or more:- E2G circuit open
ENGINE SPD Engine speed: Min.: 0 rpm, Max.: 16,383 rpm - 650 to 750 rpm for M/T: Idling
- 650 to 750 rpm for A/T: Idling
- COOLANT TEMP Engine coolant temperature: Min.: -40°C (-40°F), Max.: 140°C (284°F) 80 to 95°C (176 to 203°F): After warming up engine - If value is -40°C (-40°F): sensor circuit open
- If value is 140°C (284°F): sensor circuit shorted
INTAKE AIR Intake air temperature: Min.: -40°C (-40°F), Max.: 140°C (284°F) Equivalent to ambient air temperature - If value is -40°C (-40°F): sensor circuit open
- If value is 140°C (284°F): sensor circuit shorted
THROTTLE POS Absolute throttle position sensor: Min.: 0 %, Max.: 100 % - 10 to 22 %: Throttle valve fully closed
- 64 to 98 %: Throttle valve fully open
Read value with ignition switch ON (Do not start engine) CTPSW Closed throttle position switch: ON or OFF - ON: Throttle fully closed
- OFF: Throttle open
- VEHICLE SPD Vehicle speed: Min.: 0 km/h, Max.: 255 km/h Same as speedometer reading - ACCEL POS#1 Accelerator Pedal Position (APP) sensor No. 1 output voltage: Min.: 0 V, Max.: 5 V - 0.5 to 1.1 V: Accelerator pedal released
- 2.6 to 4.5 V: Accelerator pedal depressed
Read value with ignition switch ON (Do not start engine) ACCEL POS #2 Accelerator Pedal Position (APP) sensor No. 2 output voltage: Min.: 0V, Max.: 5V - 1.2 to 2.0 V: Accelerator pedal released
- 3.4 to 5.0 V: Accelerator pedal depressed
Read value with ignition switch ON (Do not start engine) THROTTLE POS #2 Throttle Position (TP) sensor No. 2 output voltage: Min.: 0 V, Max.: 5V - 2.1 to 3.1 V: Throttle valve fully closed
- 4.5 to 5.0 V: Throttle valve fully open
Read value with ignition switch ON (Do not start engine) THROTTLE TARGT Throttle requirement position: Min.: 0 V, Max.: 5 V 0.4 to 1.1 V: Idling - THROTL OPN DUTY Throttle actuator duty ratio (to open throttle valve): Min.: 0 %, Max.: 100% 0 %: Throttle valve fully closed - When accelerator pedal depressed, duty ratio increased
- Read value with ignition switch ON (Do not start engine)
THROTL CLS DUTY Throttle actuator closed duty ratio (to close throttle valve); Min.: 0 %, Max.: 100% 0 %: Throttle valve fully open - When accelerator pedal released, duty ratio increased
- Read value with ignition switch ON (Do not start engine)
THROTTLE MOT Whether or not throttle actuator control permitted: ON or OFF ON: Idling Read value with ignition switch ON (Do not start engine) +BM Whether or not electric throttle control system power applied: ON or OFF ON: Idling - ACCEL IDL POS Whether or not APP sensor detected engine idling: ON or OFF ON: Idling - THROTTL IDL POS Whether or not TP sensor detected engine idling: ON or OFF ON: Idling - FAIL #1 Whether or not fail-safe mode executed: ON or OFF ON: ETCS failed - FAIL #2 Whether or not fail-safe mode executed: ON or OFF ON: ETCS failed - THROTTL INITIAL Throttle valve fully closed (learned value): Min.: 0 V, Max.: 5 V 0.5 to 0.9 V - ACCEL LEARN VAL Accelerator pedal fully closed (learned value): Min.: 0 V, Max.: 5 V 0.4 to 0.8 V - THROTTLE MOT Throttle actuator current: Min.: 0 A, Max.: 20 A 0 to 3.0 A: Idling - O2S B1 S2 Heated Oxygen (HO2) sensor output voltage for bank 1 sensor 2: Min.: 0 V, Max.: 1.275 V 0.1 to 0.9 V: Driving (31 mph, 50 km/h) Performing either Active Test INJ VOL or A/F CONTROL, enables HO2 sensor voltage output to be checked AFS B1 S1 A/F sensor output voltage for bank 1 sensor 1: Min.: 0 V, Max.: 7.999 V 2.8 to 3.8 V: Idling Performing either Active Test, INJ VOL or A/F CONTROL, enables A/F sensor voltage output to be checked TOTAL FT #1 Total fuel trim value for fuel system: Min.: -0.5, Max.: 0.496 -0.2 to 0.2 - VAPOR PRESS Vapor pressure: Min.: -4.125 kPa, Max.: 2.125 kPa 0 kPa: Fuel tank cap removed - SHORT FT #1 Short-term fuel trim of bank 1: Min.: -100 %, Max.: 100 % 0 +- 20 % Short-term fuel compensation used to maintain air-fuel ratio at stoichiometric levels LONG FT #1 Long-term fuel trim of bank 1: Min.: -100 %, Max.: 100 % 0 +- 20 % Overall long-term fuel compensation that helps maintain air-fuel ratio at stoichiometric levels (moderates long-term deviations of short-term fuel trim from central value) TOTAL FT #1 Total fuel trim of bank 1: Min.: 0.5, Max.: 1.496 0.5 to 1.4: Idling - O2FT B1 S2 Short-term fuel trim associated with bank 1 sensor 2: Min.: -100 %, Max.: 100% 0 +- 20 % - AF FT B1 S1 Short-term fuel trim associated with bank 1 sensor 1: Min.: 0, Max.: 1.999 - 0.000 to 0.999: Lean
- 1: Stoichiometric air-fuel ratio
- 1.001 to 1.999: Rich
- FUEL SYS #1 Fuel system status (Bank 1): OL or CL or OL DRIVE or OL FAULT or CL FAULT CL: Idling with warm engine - OL (Open Loop): Conditions for closed loop not yet satisfied
- CL (Closed Loop): Using AF sensor as feedback for fuel control
- OL DRIVE: Open loop due to driving conditions (fuel enrichment)
- OL FAULT: Open loop due to detected system fault
- CL FAULT: Closed loop but AF sensor used for fuel control malfunctioning
FC IDL Fuel cut idling: ON or OFF ON: Fuel cut operation ON: Throttle valve fully closed and engine speed 1,500 rpm or more MIL MIL status: ON or OFF ON: MIL ON - STARTER SIG Starter signal: ON or OFF ON: Cranking - A/C SIG A/C signal: ON or OFF ON: A/C ON - PNP SW [NSW] (1) Park/Neutral position switch signal: ON or OFF ON: P or N position - ELECT LOAD SIG Electrical load signal: ON or OFF - ON: Taillight switch ON
- ON: Defogger switch ON
- STOP LIGHT SW Stop light switch: ON or OFF - ON: Brake pedal depressed
- OFF: Brake pedal released
- PS OIL PRESS SW Power steering oil pressure switch signal: ON or OFF - ON: While turning steering wheel
- OFF: While not turning steering wheel
ON: Idle-up control activated PS SIGNAL Power steering signal: ON or OFF ON: When steering wheel first turned after ignition switch turned to ON This signal status usually ON until ignition switch turned OFF FUEL PUMP/SPD Fuel pump/speed status: ON/H, OFF/M or L ON/H: Idling - A/C MAG CLUTCH A/C magnet clutch status: ON or OFF ON: A/C magnet clutch ON - EVAP VSV EVAP VSV: ON or OFF ON: VSV operation EVAP VSV controlled by ECM (ground side duty control) VVT CTRL B1 VVT control status (bank 1): ON or OFF ON: VVT system operation - VACUUM PUMP Key-off EVAP system leak detection pump status: ON or OFF - Active test support data IGNITION Ignition counter: Min.: 0, Max.: 400 0 to 400 - CYL#1, #2, #3, #4 Misfire ratio of cylinder 1 to 4: Min.: 0 %, Max.: 50 % 0% Only displayed when idling MISFIRE RPM Engine RPM for first misfire range: Min.: 0 rpm, Max.: 6,375 rpm 0 rpm: Misfire 0 - MISFIRE LOAD Engine load for first misfire range: Min.: 0 g/rev, Max.: 3.98 g/rev 0 g/rev: Misfire 0 - FC TAU Fuel cut during very light load: ON or OFF ON: Fuel cut operation Fuel cut performed under very light load to prevent incomplete engine combustion #CODES #Codes: Min.: 0, Max.: 255 Number of detected DTCs - SPD TEST Check mode result for vehicle speed sensor. COMPL or INCMPL - - MISFIRE TEST Check mode result for misfire monitor. COMPL or INCMPL - - OXS1 TEST Check mode result for HO2 sensor. COMPL or INCMPL - - OBD CERT OBD requirement OBD2 - # CARB CODES Emission related DTCs - Number of emission related DTCs O2S (A/FS) MON O2S (A/FS) monitor. NOT AVL or AVAIL - - EVAP MON EVAP monitor: NOT AVL or AVAIL - - CAT MON Catalyst monitor: NOT AVL or AVAIL - - CHECK MODE Check mode: ON or OFF ON: Check mode ON See CHECK MODE PROCEDURE MIL ON RUN DIST Distance vehicle driven with illuminated MIL: Min.: 0 km, Max.: 65,535 km Distance after DTC detected - (1) A/T only Normal Condition: If no idling conditions are specified, the transmission gear selector lever should be in the N or P position, and the A/C switch and all accessory switches should be OFF.
- ACTIVE TEST
HINT:
Performing an ACTIVE TEST enables components including the relays, VSV (Vacuum Switching Valve), and actuators, to be operated without removing any parts. The ACTIVE TEST can be performed with an intelligent tester. Performing an ACTIVE TEST as the first step of troubleshooting is one method of shortening diagnostic time. DATA LIST can be displayed during ACTIVE TESTs.
- Connect an intelligent tester to the DLC3.
- Turn the ignition switch to ON.
- Turn the tester ON.
- Select the following menu items: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST.
- Perform the ACTIVE TEST by referring to the table below.TESTER DISPLAY AND DIAGNOSTIC NOTES
Tester Display Test Part Control Range Diagnostic Notes INJ VOL Change injection volume Between -12 % and 25 % - All injectors tested at the same time
- Perform test at less than 3,000 rpm
- Injection volume can be changed in 1 % graduations within control range
A/F CONTROL Change injection volume Lower by 12.5% or increase by 25% - Perform test at less than 3,000 rpm
- A/F CONTROL enables checking and graphing of A/F (Air-Fuel Ratio) sensor and Heated Oxygen (HO2) sensor voltage outputs
- To conduct test, select following menu items: ACTIVE TEST /A/F CONTROL / USER DATA / AFS B1S1 and O2S B1S2, and press YES and ENTER followed by F4
IAC DUTY RATIO Control IAC duty ratio Between 0 % and 90 % Perform test under following conditions: - Engine speed: Idling
- Vehicle speed: 0 mph (0 km/ h)
- Battery voltage: 8.5 V or more
EVAP VSV (ALONE) Activate EVAP VSV control ON/OFF - A/C MAG CLUTCH Activate A/C magnet clutch ON/OFF - FUEL PUMP/SPD Activate fuel pump (C/OPN Relay) ON/OFF - VVT CTRL B1 Turn on and off OCV (Oil Control Valve) ON/OFF - Engine stalls or idles roughly when OCV turned ON
- Normal engine running or idling when OCV off
TC/TE1 Turn on and off TC and TE1 connection ON/OFF - ON: TC and TE1 connected
- OFF: TC and TE1 disconnected
FCIDL PROHBT Prohibit idling fuel cut control ON/OFF - VENT VALVE (ALONE) Activate vent valve (built into pump module) ON/OFF - VCUUM PUMP Activate vacuum pump (built into pump module) ON/OFF -
- SYSTEM CHECK
HINT:
Performing a SYSTEM CHECK enables the system, which consists of multiple actuators, to be operated without removing any parts. In addition, it can show whether or not any DTCs are set, and can detect potential malfunctions in the system. The SYSTEM CHECK can be performed with an intelligent tester.
- Connect an intelligent tester to the DLC3.
- Turn the ignition switch to ON.
- Turn the tester ON.
- Select the following menu items: DIAGNOSIS / ENHANCED OBD II / SYSTEM CHECK.
- Perform the SYSTEM CHECK by referring to the table below.TESTER DISPLAY AND DIAGNOSTIC NOTES
Tester Display Test Part Control Range Diagnostic Notes EVAP SYS CHECK (AUTO OPERATION) Perform 4 steps in order to operate EVAP key-off monitor automatically 35°C (95°F) or less - If no DTCs in PENDING CODE after performing this test, system functioning normally
- Refer to EVAP SYSTEM
EVAP SYS CHECK (MANUAL OPERATION) Perform 4 steps in order to operate EVAP key-off monitor manually 35°C (95°F) or less - Used to detect malfunctioning parts
- Refer to EVAP SYSTEM