Service Data
SERVICE DATA REFERENCE CHART
| Battery | ||
| Voltage | Standard | 12.5 to 12.9 V at 20°C(68°F) |
| Charging circuit without load | ||
| Amperage | Standard | 10 A or less |
| Voltage | Standard | 12.9 to 14.9 V |
| Charging circuit with load | ||
| Amperage | Standard | 30 A or more |
| Generator brush holder assembly | ||
| Brush length | Standard | 9.5 to 11.5 mm (0.374 to 0.453 in.) |
| Minimum | 4.5 mm (0.177 in.) | |
| Generator regulator assembly | ||
| Resistance | B and F | When the positive and negative poles of terminals F and B are switched over, there is a resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction |
| E and F | When the positive and negative poles of terminals F and E are switched over, there is a resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction | |
| Generator holder w/ rectifier | ||
| Resistance | Positive (+) and each rectifier terminal | When the positive and negative poles of the positive (+) terminal and each rectifier terminal are switched over, there is a resistance of below 1 O in one direction but 10 kΩ or higher in the other direction |
| Negative (-) and each rectifier terminal | When the positive and negative poles of the negative (-) terminal and each rectifier terminal are switched over, there is a resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction | |
| Generator rotor assembly | ||
| Resistance | at 20°C (68°F) | 2.1 to 2.5 Ω |
| Slip ring diameter | Standard | 14.2 to 14.4 mm (0.559 to 0.567 in.) |
| Minimum | 14.0 mm (0.551 in.) | |
| Generator rectifier end frame | ||
| Resistance | Coil wires | Below 1 Ω |
| Coil wire and body | 1 MΩ or higher | |