Service Data
Skid Control Buzzer
SKID CONTROL BUZZER - SERVICE DATA
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) voltage → Terminal 2 | Skid control buzzer sounds |
| Battery negative (-) → Terminal 1 |
VSC OFF Switch
VSC OFF SWITCH - SERVICE DATA
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3-6 | Pressed | Below 1 Ω |
| Not Pressed | 10 kΩ or higher |
CRAWL Switch
CRAWL SWITCH - SERVICE DATA
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 (ECU1) - 20 (E) | Speed Selector: MID | 10 kΩ or higher |
| Speed Selector: HI | ||
| Speed Selector: LO | Below 1 Ω | |
| 4 (ECU2) - 20 (E) | Speed Selector: MID | 10 kΩ or higher |
| Speed Selector: HI | Below 1 Ω | |
| Speed Selector: LO | ||
| 2 (HSW) - 20 (E) | ON/OFF: Pressed | Below 1 Ω |
| ON/OFF: Not pressed | 10 kΩ or higher |
BRK LP Relay
BRK LP RELAY - SERVICE DATA
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3-4 | Battery positive voltage applied to terminal 1 and battery negative voltage to terminal 2 | 10 kΩ or higher |
| Battery positive voltage not applied to terminal 1 and battery negative voltage applied to terminal 2 | Below 1 Ω | |
| 3-5 | Battery positive voltage applied to terminal 1 and battery negative voltage to terminal 2 | Below 1 Ω |
| Battery positive voltage not applied to terminal 1 and battery negative voltage applied to terminal 2 | 10 kΩ or higher |