Circuit Opening Relay: Inspection
- INSPECT E.F.I. CIRCUIT OPENING RELAY ASSEMBLY
- Inspect the resistance.
- Using an ohmmeter, measure the resistance between the terminals.
Resistance
TESTER CONNECTIONS AND SPECIFIED CONDITIONSTester Connection Specified Condition 3 - 5 10 kΩ or higher 3 - 5 Below 1 Ω (Apply battery voltage to terminal 1 and 2) Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the E.F.I, circuit opening relay assembly.
- Using an ohmmeter, measure the resistance between the terminals.
- Inspect the resistance.