Front Speed Sensor: Inspection
- INSPECT FRONT SPEED SENSOR
- Make sure that there is no looseness at the locking part and the connecting part of the connectors.
- Disconnect the front speed sensor connectors.
- Measure the resistance according to the value (s) in the table below.
Resistance:
LH
RESISTANCE SPECIFICATIONTester Connection Specified Condition A8-1 (FL+) - A8-2 (FL-) 1.22 to 0.92 kΩ A8-1 (FL+) - Body ground 10 kΩ or higher A8-2 (FL-) - Body ground 10 kΩ or higher RH
RESISTANCE SPECIFICATIONTester Connection Specified Condition A30-1 (FR+) - A30-2 (FR-) 1.22 to 0.92 kΩ A30-1 (FR+) - Body ground 10 kΩ or higher A30-2 (FR-) - Body ground 10 kΩ or higher