VSC OFF SWITCH (w/ VSC): Inspection
- INSPECT VSC OFF SWITCH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFIED CONDITIONSTester Connection Switch Condition Specified Condition 3 - 6 Released 10 kΩ or higher 3 - 6 Pushed in Below 25 Ω If the result is not as specified, replace the switch.
- Check illumination operation.
Standard
ILLUMINATION CONDITIONSTester Connection Condition Specified Condition 4 (Battery negative (-)) - 5 (Battery positive (+)) Always LED illuminates If the result is not as specified, replace the VSC off switch.
- Measure the resistance according to the value(s) in the table below.