Inspection Procedure
- CHECK MIL
- Check that the MIL (Malfunction Indicator Lamp) lights up when turning the power switch ON (IG).
OK:
MIL lights up.
OK: SYSTEM IS OK
NG: Go to next step.
- Check that the MIL (Malfunction Indicator Lamp) lights up when turning the power switch ON (IG).
- CHECK CONNECTION BETWEEN TECHSTREAM AND ECM
- Connect Techstream to the DLC3.
- Turn the power switch ON (IG) and turn Techstream ON.
- Check the connection between Techstream and ECM.
Result
RESULT CHARTCondition Proceed to Communication is possible A Communication is not possible B
A: GO TO MIL CIRCUIT
B: Go to next step.
- CHECK ECM (VC VOLTAGE)
- CHECK MIL (THROTTLE POSITION SENSOR)
- Disconnect the T3 throttle body connector.
- Turn the power switch ON (IG).
- Check the MIL
Result
RESULT CHARTCondition Proceed to MIL illuminates A MIL does not illuminate B
A: REPLACE THROTTLE BODY
B: Go to next step.
- CHECK MIL (WATER VALVE)
- Disconnect the W5 water valve connector.
- Turn the power switch ON (IG).
- Check the MIL
Result
RESULT CHARTCondition Proceed to MIL illuminates A MIL does not illuminate B
A: REPLACE WATER VALVE
B: Go to next step.
- CHECK MIL (CANISTER PUMP MODULE)
- Disconnect the V7 canister pump module connector.
- Turn the power switch ON (IG).
- Check the MIL
Result
RESULT CHARTCondition Proceed to MIL illuminates A MIL does not illuminate B
A: REPLACE CHARCOAL CANISTER ASSEMBLY
B: Go to next step.
- CHECK MIL (VAPOR PRESSURE SENSOR)
- Disconnect the V6 vapor pressure sensor connector.
- Turn the power switch ON (IG).
- Check the MIL
Result
RESULT CHARTCondition Proceed to MIL illuminates A MIL does not illuminate B
A: REPLACE VAPOR PRESSURE SENSOR
B: Go to next step.
- CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
- Disconnect the T3 throttle body connector.
- Disconnect the W5 water valve connector.
- Disconnect the V7 canister pump module connector.
- Disconnect the V6 vapor pressure sensor connector.
- Disconnect the E4 ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition E4-18 (VC) - Body ground 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE ECM