Inspection [08/2016 - ]: Procedure
- INSPECT TSS C HTR RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher 3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω 1 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher 2 - 3 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher If the result is not as specified, replace the TSS C HTR relay.
- Measure the resistance according to the value(s) in the table below.