On-Vehicle Inspection [08/2016 - ]: Procedure
- INSPECT EFI MAIN RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied 10 kΩ or higher 3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay.
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 2 EFI MAIN RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied 10 kΩ or higher 3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay.
- Measure the resistance according to the value(s) in the table below.
- INSPECT C/OPN RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied 10 kΩ or higher 3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay.
- Measure the resistance according to the value(s) in the table below.
- INSPECT IG2 RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied 10 kΩ or higher 3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay.
- Measure the resistance according to the value(s) in the table below.
- INSPECT AIR FUEL RATIO SENSOR HEATER RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied 10 kΩ or higher 3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay.
- Measure the resistance according to the value(s) in the table below.
- INSPECT DIRECT INJECTOR RELAY (D INJ)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltagenot applied between terminals 1 and 2 10 kΩ or higher 3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the injector relay (D INJ).
- Measure the resistance according to the value(s) in the table below.