Inspection [11/2015 - 12/2018]: Procedure
- INSPECT SKID CONTROL BUZZER
- Make sure that there is no looseness in the locking part and connecting part of the connector.
- Disconnect the skid control buzzer connector.
- Check the connector and terminals for deformation and corrosion.
OK
No deformation or corrosion.
- Connect a positive (+) lead from the battery to terminal 1, and a negative (-) lead to terminal 2 of the skid control buzzer, and check that the buzzer sounds.
Standard
(F41)
(F41)
Tester Connection Specified Condition F41-1 - Auxiliary battery (+)
F41-2 - Auxiliary battery (-)The skid control buzzer sounds If the result is not as specified, replace the skid control buzzer.
- Make sure that there is no looseness in the locking part and connecting part of the connector.