Rear Motor Generator Control System
REAR MOTOR GENERATOR CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION
| DTC Code | Description |
|---|---|
| P0A4516 | Drive Motor "B" Position Sensor Circuit Voltage Below Threshold |
| P0A451F | Drive Motor "B" Position Sensor Circuit Intermittent |
| P0A4521 | Drive Motor "B" Position Sensor Signal Amplitude < Minimum |
| P0A4522 | Drive Motor "B" Position Sensor Signal Amplitude > Maximum |
| P0A6912 | Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery |
| P0A6914 | Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open |
| P0A691C | Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range |
| P0A691F | Drive Motor "B" Phase V Current(High Resolution) Circuit Intermittent |
| P0A6C12 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery |
| P0A6C14 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open |
| P0A6C1C | Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range |
| P0A6C1F | Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent |
| P0A7972 | Drive Motor "B" Inverter Actuator Stuck Open |
| P0A7973 | Drive Motor "B" Inverter Actuator Stuck Closed |
| P0A799E | Drive Motor "B" Inverter Stuck On |
| P0A9100 | Drive Motor "B" Performance |
| P0AF211 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground |
| P0AF215 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open |
| P0AF21C | Drive Motor Inverter Temperature Sensor "B" Circuit Voltage Out of Range |
| P0BF112 | Drive Motor "B" Phase U Current Sensor Circuit Short to Battery |
| P0BF114 | Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BF11F | Drive Motor "B" Phase U Current Sensor Circuit Intermittent |
| P0BF128 | Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BF512 | Drive Motor "B" Phase V Current Sensor Circuit Short to Battery |
| P0BF514 | Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BF51F | Drive Motor "B" Phase V Current Sensor Circuit Intermittent |
| P0BF528 | Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BF912 | Drive Motor "B" Phase W Current Sensor Circuit Short to Battery |
| P0BF914 | Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BF91F | Drive Motor "B" Phase W Current Sensor Circuit Intermittent |
| P0BF928 | Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BFE62 | Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure |
| P0C021D | Drive Motor "B" System Circuit Current Out of Range |
| P0C1A00 | Drive Motor "B" Execution Torque Performance |
| P0C5513 | Drive Motor "B" Position Sensor Circuit "A" Circuit Open |
| P0C5516 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C5517 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C551F | Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent |
| P0C5F13 | Drive Motor "B" Position Sensor Circuit "B" Circuit Open |
| P0C5F16 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5F17 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5F1F | Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent |
| P1BF946 | Internal Control Module (EEPROM Estimated Temperature Information) Calibration / Parameter Memory Failure |
| P1BFA46 | Internal Control Module (EEPROM Resolver Learning Value) Calibration / Parameter Memory Failure |
| P1C2C1C | Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range |
| P1C2C49 | Drive Motor "B" Control Module AD Converter Circuit Internal Electronic Failure |
| P1C5E19 | Drive Motor "B" Inverter Circuit Current Above Threshold |
| P1C631F | Drive Motor "B" Control Module Offset Power Circuit Intermittent |
| P1C661F | Drive Motor "B" Control Module Circuit Intermittent |
| P1C681F | Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent |
| P1CAE49 | Drive Motor "B" Position Sensor Internal Electronic Failure |
| P1CB138 | Drive Motor "B" Position Sensor REF Signal Frequency Incorrect |
| P262C1C | Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range |
| P310B1F | Communication Error from Drive Motor "A" to Drive Motor "B" Circuit Intermittent |
| P310B83 | Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect |
| P310B86 | Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid |
| P310B87 | Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message |
| P32CF1F | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Circuit Intermittent |
| P32CF83 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect |
| P32CF86 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid |
| P32CF87 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message |