On-Vehicle Inspection [12/2024 - ]: Procedure
- INSPECT NO. 1 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI MAIN NO. 1)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher kΩ 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω Ω If the result is not as specified, replace the No. 1 electronic fuel injection main relay (EFI MAIN NO. 1).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 2 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI MAIN NO. 2)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher kΩ 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω Ω If the result is not as specified, replace the No. 2 electronic fuel injection main relay (EFI MAIN NO. 2).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 3 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI MAIN NO. 3)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher kΩ 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω Ω If the result is not as specified, replace the No. 3 electronic fuel injection main relay (EFI MAIN NO. 3).
- Measure the resistance according to the value(s) in the table below.
- INSPECT ELECTRONIC DRIVER UNIT RELAY (EDU)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher kΩ 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω Ω If the result is not as specified, replace the electronic driver unit relay (EDU).
- Measure the resistance according to the value(s) in the table below.
- INSPECT INJECTOR RELAY (IGT/INJ MAIN)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher kΩ 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω Ω If the result is not as specified, replace the injector relay (IGT/INJ MAIN).
- Measure the resistance according to the value(s) in the table below.
- INSPECT IGP RELAY (IGP NO. 1)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher kΩ 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω Ω If the result is not as specified, replace the IGP relay (IGP NO. 1).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 2 IGP RELAY (IGP NO. 2)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher kΩ 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω Ω If the result is not as specified, replace the No. 2 IGP relay (IGP NO. 2).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 3 IGP RELAY (IGR NO. 3)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher kΩ 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω Ω If the result is not as specified, replace the No. 3 IGP relay (IGR NO. 3).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 4 IGP RELAY (IGR NO. 4)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher kΩ 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω Ω If the result is not as specified, replace the No. 4 IGP relay (IGR NO. 4).
- Measure the resistance according to the value(s) in the table below.