Vehicle Control DTCS
VEHICLE CONTROL DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION
| DTC | Description |
|---|---|
| P0120-11 | Throttle/Pedal Position Sensor/Switch "A" - Circuit Short To Ground |
| P0120-12 | Throttle/Pedal Position Sensor/Switch "A" - Circuit Short To Battery |
| P0120-16 | Throttle/Pedal Position Sensor/Switch "A"- Circuit Voltage Below Threshold |
| P0120-17 | Throttle/Pedal Position Sensor/Switch "A"- Circuit Voltage Above Threshold |
| P0120-1F | Throttle/Pedal Position Sensor/Switch "A" - Circuit Intermittent |
| P01AF-81 | Battery Energy Control Module "A" - Invalid Serial Data Received |
| P01AF-87 | Battery Energy Control Module "A" - Missing Message |
| P0220-11 | Throttle/Pedal Position Sensor/Switch "B" - Circuit Short To Ground |
| P0220-12 | Throttle/Pedal Position Sensor/Switch "B" - Circuit Short To Battery |
| P0220-16 | Throttle/Pedal Position Sensor/Switch "B"- Circuit Voltage Below Threshold |
| P0220-17 | Throttle/Pedal Position Sensor/Switch "B"- Circuit Voltage Above Threshold |
| P0220-1F | Throttle/Pedal Position Sensor/Switch "B" - Circuit Intermittent |
| P0513-00 | Incorrect Immobilizer Key |
| P0530-11 | A/C Refrigerant Pressure Sensor "A" - Circuit Short To Ground |
| P0530-12 | A/C Refrigerant Pressure Sensor "A"- Circuit Short To Battery |
| P0530-1F | A/C Refrigerant Pressure Sensor "A" - Circuit Intermittent |
| P0630-56 | VIN Not Programmed Or Incompatible |
| P0633-00 | Immobilizer Key Not Programmed |
| P0A17-01 | Regen Brake - General Electric Failure |
| P0A1E-00 | Battery Energy Control Module "A" - E2E (End-To-End) Testing |
| P0A1F-82 | Battery Energy Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| P0A1F-83 | Battery Energy Control Module "A" - Value Of Signal Protection Calculation Incorrect |
| P0A9B-11 | Hybrid/EV Battery Temperature Sensor "A" - Circuit Short To Ground |
| P0A9B-12 | Hybrid/EV Battery Temperature Sensor "A"- Circuit Short To Battery |
| P0A9B-1F | Hybrid/EV Battery Temperature Sensor "A"- Circuit Intermittent |
| P0AA0-72 | Hybrid/EV Battery Positive Contactor - Actuator Stuck Open |
| P0AA0-73 | Hybrid/EV Battery Positive Contactor - Actuator Stuck Closed |
| P0AA6-00 | Hybrid/EV Battery Voltage System Isolation Fault |
| P0AA7-00 | Battery Energy Control Module "A" High-Voltage Interlock Loop (HVIL) |
| P0C47-04 | Hybrid/EV Battery Pack Coolant Pump "A" - System Internal Failures |
| P0C47-07 | Hybrid/EV Battery Pack Coolant Pump "A" - Mechanical Failure |
| P0C47-09 | Hybrid/EV Battery Pack Coolant Pump "A" - Component Failure |
| P0C47-11 | Hybrid/EV Battery Pack Coolant Pump - Circuit Short To Ground |
| P0C47-12 | Hybrid/EV Battery Pack Coolant Pump - Circuit Short To Battery |
| P0C47-13 | Hybrid/EV Battery Pack Coolant Pump - Circuit Open |
| P0C47-19 | Hybrid/EV Battery Pack Coolant Pump "A" - Circuit Current Above Threshold |
| P0C47-86 | Hybrid/EV Battery Pack Coolant Pump "A" - Signal Invalid |
| P0C47-94 | Hybrid/EV Battery Pack Coolant Pump "A" - Unexpected Operation |
| P0C47-98 | Hybrid/EV Battery Pack Coolant Pump "A" - Component Or System Over Temperature |
| P0C48-11 | Hybrid/EV Electronics Coolant Radiation Fan "B" Control - Circuit Short To Ground |
| P0C48-12 | Hybrid/EV Electronics Coolant Radiation Fan "B" Control - Circuit Short To Battery |
| P0C48-13 | Hybrid/EV Electronics Coolant Radiation Fan "B" Control - Circuit Open |
| P0C49-04 | Hybrid/EV Battery Pack Coolant Pump "2" - System Internal Failures |
| P0C49-07 | Hybrid/EV Battery Pack Coolant Pump "2" - Mechanical Failure |
| P0C49-09 | Hybrid/EV Battery Pack Coolant Pump "2" - Component Failure |
| P0C49-11 | Hybrid/EV Battery Pack Coolant Pump 2 - Circuit Short To Ground |
| P0C49-12 | Hybrid/EV Battery Pack Coolant Pump 2 - Circuit Short To Battery |
| P0C49-13 | Hybrid/EV Battery Pack Coolant Pump 2 - Circuit Open |
| P0C49-19 | Hybrid/EV Battery Pack Coolant Pump "2" - Circuit Current Above Threshold |
| P0C49-86 | Hybrid/EV Battery Pack Coolant Pump "2" - Signal Invalid |
| P0C49-94 | Hybrid/EV Battery Pack Coolant Pump "2" - Unexpected Operation |
| P0C49-98 | Hybrid/EV Battery Pack Coolant Pump "2" - Component Or System Over Temperature |
| P0CC1-04 | Drive Motor Coolant Pump "A" - System Internal Failures |
| P0CC1-07 | Drive Motor Coolant Pump "A" - Mechanical Failure |
| P0CC1-09 | Drive Motor Coolant Pump "A" - Component Failure |
| P0CC1-11 | Drive Motor Coolant Pump - Circuit Short To Ground |
| P0CC1-12 | Drive Motor Coolant Pump - Circuit Short To Battery |
| P0CC1-13 | Drive Motor Coolant Pump - Circuit Open |
| P0CC1-19 | Drive Motor Coolant Pump "A" - Circuit Current Above Threshold |
| P0CC1-86 | Drive Motor Coolant Pump "A" - Signal Invalid |
| P0CC1-94 | Drive Motor Coolant Pump "A" - Unexpected Operation |
| P0CC1-98 | Drive Motor Coolant Pump "A" - Component Or System Over Temperature |
| P0CCC-11 | Charge Port Door "A" Position Sensor - Circuit Short To Ground |
| P0CCC-12 | Charge Port Door "A" Position Sensor - Circuit Short To Battery |
| P0CCC-1F | Charge Port Door "A" Position Sensor - Circuit Intermittent |
| P0CD1-11 | Charge Port Door "A" Unlock Control - Circuit Short To Ground |
| P0CD1-12 | Charge Port Door "A" Unlock Control - Circuit Short To Battery |
| P0CD1-13 | Charge Port Door "A" Unlock Control - Circuit Open |
| P0CD2-01 | Charge Port Door "A" Illumination Light - General Electric Failure |
| P0CEE-11 | Hybrid/EV Electronics Coolant Temperature Sensor "A" - Circuit Short To Ground |
| P0CEE-12 | Hybrid/EV Electronics Coolant Temperature Sensor "A"- Circuit Short To Battery |
| P0CEE-1F | Hybrid/EV Electronics Coolant Temperature Sensor "A" - Circuit Intermittent |
| P0CF2-00 | Control Pilot Signal Voltage |
| P0CF3-96 | Charge Port Control Pilot - Component Internal Failure |
| P0D56-11 | Proximity Detection "A"- Circuit Short To Ground |
| P0D56-12 | Proximity Detection "A"- Circuit Short To Battery |
| P0D56-1F | Proximity Detection "A"- Circuit Intermittent |
| P0D56-96 | Proximity Detection "A" - Component Internal Failure |
| P0D91-96 | Battery Charger Coupler Lock Control - Component Internal Failure |
| P0E5F-98 | Battery Charger Coupler Temperature "A" - Component Or System Over Temperature |
| P0E65-08 | Battery Charger Control - Bus Signal/Message Failure |
| P0E65-68 | Battery Charger Control - Event Information |
| P0E65-96 | Battery Charger Control - Component Internal Failure |
| P0E85-71 | Battery Charger "B" Temperature - Actuator Stuck |
| P0E85-98 | Battery Charger "B" - Component Or System Over Temperature |
| P0E88-25 | Battery Charger "B" Input Current - Signal Shape/Waveform Failure |
| P0EEE-98 | Battery Charger Coupler Temperature "B" - Component Or System Over Temperature |
| P1003-16 | Multiway Valve "A"- Circuit Voltage Below Threshold |
| P1003-17 | Multiway Valve "A"- Circuit Voltage Above Threshold |
| P1003-81 | Multiway Valve "A" - Invalid Serial Data Received |
| P1003-87 | Multiway Valve "A" - Missing Message |
| P1003-96 | Multiway Valve "A" - Component Internal Failure |
| P1003-98 | Multiway Valve "A"- Component Or System Over Temperature |
| P1011-01 | Air Flow Shutter "A" Control Module - General Electric Failure |
| P1011-07 | Air Flow Shutter "A" Control Module - Mechanical Failure |
| P1011-16 | Air Flow Shutter "A" Control Module - Circuit Voltage Below Threshold |
| P1011-17 | Air Flow Shutter "A" Control Module Above Threshold |
| P1011-54 | Air Flow Shutter "A" Control Module - Missing Calibration |
| P1011-81 | Air Flow Shutter "A" Control Module - Invalid Serial Data Received |
| P1011-87 | Air Flow Shutter "A" Control Module - Missing Message |
| P1011-97 | Air Flow Shutter "A" Control Module - Component Or System Operation Obstructed Or Blocked |
| P1011-98 | Air Flow Shutter "A" Control Module - Component Or System Over Temperature |
| P1012-08 | A/C Compressor "B" - Invalid Serial Data Received |
| P1012-87 | A/C Compressor "B" - Missing Message |
| P1013-16 | A/C Compressor "A" - Circuit Voltage Below Threshold |
| P1013-17 | A/C Compressor "A" - Circuit Voltage Above Threshold |
| P1013-1D | A/C Compressor "A" - Circuit Current Out Of Range |
| P1013-49 | A/C Compressor "A" - Internal Electronic Failure |
| P1013-98 | A/C Compressor "A" Component Or System Over Temperature |
| P1014-13 | A/C Compressor "B" - Circuit Open |
| P1014-19 | A/C Compressor "B" - Circuit Current Above Threshold |
| P1014-96 | A/C Compressor "B" - Component Internal Failure |
| P1014-98 | A/C Compressor "B" - Component Or System Over Temperature |
| P1015-16 | A/C Compressor "B" HV-Circuit Voltage Below Threshold |
| P1015-17 | A/C Compressor "B" HV-Circuit Voltage Above Threshold |
| P1016-19 | A/C Compressor "B" Sensor-Circuit Current Above Threshold |
| P1016-1C | A/C Compressor "B" Sensor-Circuit Voltage Out Of Range |
| P1016-1D | A/C Compressor "B" Sensor - Circuit Current Out Of Range |
| P1016-25 | A/C Compressor "B" Sensor - Signal Shape/Waveform Failure |
| P1017-16 | A/C Compressor "B" LV - Circuit Voltage Below Threshold |
| P1017-17 | A/C Compressor "B" LV - Circuit Voltage Above Threshold |
| P1018-99 | A/C Compressor "B" Overload - Exceeded Learning Limit |
| P1019-99 | A/C Compressor "B" Stall - Exceeded Learning Limit |
| P101E-81 | High Voltage Heater "A" - Invalid Serial Data Received |
| P101E-87 | High Voltage Heater "A" - Missing Message |
| P101E-92 | Cabin Heater "A" - Performance Or Incorrect Operation |
| P101E-94 | Cabin Heater "A" - No Operation |
| P101E-96 | Cabin Heater "A" - Component Internal Failure |
| P101E-98 | Cabin Heater "A" - Component Or System Over Temperature |
| P101E-9A | Cabin Heater "A" - Component Or System Operating Conditions |
| P101F-1C | High Voltage Heater "A" High Voltage - Circuit Voltage Out Of Range |
| P1021-81 | Acoustic Vehicle Alerting System (AVAS) Control Module "A" - Invalid Serial Data Received |
| P1021-87 | Acoustic Vehicle Alerting System (AVAS) Control Module "A"- Missing Message |
| P1026-11 | LTR2 Temperature Sensor "A" - Circuit Short To Ground |
| P1026-12 | LTR2 Temperature Sensor "A" - Circuit Short To Battery |
| P1026-1F | LTR2 Temperature Sensor "A" - Circuit Intermittent |
| P1030-00 | Powertrain Activation Comparison Confirmed Error |
| P1031-00 | Crash Detection Confirmed Error |
| P1032-00 | Actual Gear Comparison Confirmed Error |
| P1035-00 | Target Gear Comparison Confirmed Error |
| P1036-00 | Sum Torque Request Comparison Confirmed Error Based On VAT (Delta_TorquexFault_Tolerant_Time) Curve |
| P1037-00 | Unintended Movement Sum Torque Request Comparison Confirmed Error |
| P1038-00 | Unintended Torque at Neutral Sum Torque Request Comparison Confirmed Error |
| P103A-00 | Opposite Direction Movement Sum Torque Sign Comparison Confirmed Error |
| P103B-00 | Drive Motor Control Module "A" Torque Request Comparison Confirmed Error |
| P103C-00 | Drive Motor Control Module 'B" Torque Request Comparison Confirmed Error |
| P103D-00 | Drive Motor Control Module "A" & "B" Torque Request Sum Torque Feedback Comparison Confirmed Error |
| P103E-00 | Drive Motor Control Module "A" & "B" Torque Request Sign Comparison Confirmed Error (Yaw) |
| P103F-00 | Drive Motor Control Module "A" - E2E (End-To-End) Testing For CAN Message 0x1F8 |
| P1040-84 | AC Charging Intake Temperature Sensor - Signal Below Allowable Range |
| P1040-85 | AC Charging Intake Temperature Sensor - Signal Above Allowable Range |
| P1042-84 | Ambient Pressure Sensor - Signal Below Allowable Range |
| P1042-85 | Ambient Pressure Sensor - Signal Above Allowable Range |
| P1043-16 | LV Battery - Circuit Voltage Below Threshold |
| P1043-17 | LV Battery - Circuit Voltage Above Threshold |
| P1050-29 | Charger Gun Lock Pin - Signal Invalid |
| P1050-72 | Charge Gun Lock Pin - Actuator Stuck Open |
| P1050-73 | Charge Gun Lock Pin - Actuator Stuck Closed |
| P1051-84 | Control Pilot Signal Frequency Range Check - Signal Below Allowable Range |
| P1051-85 | Control Pilot signal frequency range check - Signal Above Allowable Range |
| P1054-84 | Control Pilot Switch/S2 switch - Signal Below Allowable Range |
| P1054-85 | Control Pilot Switch/S2 Switch - Signal Above Allowable Range |
| P1056-13 | Charge Plug Interlock - Circuit Open |
| P1056-19 | Charge Plug Interlock - Circuit Current Above Threshold |
| P1056-4B | Charge Plug Interlock - Over Temperature |
| P1056-84 | Charge Plug Interlock - Signal Below Allowable Range |
| P1056-85 | Charge Plug Interlock - Signal Above Allowable Range |
| P1056-92 | Charge Plug Interlock - Performance Or Incorrect Operation |
| P1057-11 | Charge Plug Interlock 1 - Circuit Short To Ground |
| P1057-12 | Charge Plug Interlock 1 - Circuit Short To Battery |
| P1058-11 | Charge Plug Interlock 2 - Circuit Short To Ground |
| P1058-12 | Charge Plug Interlock 2 - Circuit Short To Battery |
| P105D-17 | Charge Plug Control Pilot Signal - Circuit Voltage Above Threshold |
| P105D-38 | Charge Plug Control Pilot Signal - Signal Frequency Incorrect |
| P105E-72 | Charge Plug S2 Switch - Actuator Stuck Open |
| P105E-73 | Charge Plug S2 Switch - Actuator Stuck Closed |
| P105F-84 | DC Charging Intake Temperature Sensor 2 - Signal Below Allowable Range |
| P105F-85 | DC Charging Intake Temperature Sensor 2 - Signal Above Allowable Range |
| P1061-84 | DC Charging Intake Temperature Sensor 1 - Signal Below Allowable Range |
| P1061-85 | DC Charging Intake Temperature Sensor 1 - Signal Above Allowable Range |
| P1063-85 | High Level Communication - Signal Above Allowable Range |
| P1064-84 | Power Line Communication Chip Supply Pin - Signal Below Allowable Range |
| P1064-85 | Power Line Communication Chip Supply Pin - Signal Above Allowable Range |
| P1065-11 | Main Relay - Circuit Short To Ground |
| P1065-12 | Main Relay - Circuit Short To Battery |
| P1065-13 | Main Relay - Circuit Open |
| P1066-92 | Power Line Communication - Performance Or Incorrect Operation |
| P1067-84 | Power Line Communication Chip Temperature - Signal Below Allowable Range |
| P1067-85 | Power Line Communication Chip Temperature - Signal Above Allowable Range |
| P106B-29 | Proximity Pilot Signal Voltage - Signal Invalid |
| P106C-16 | Sensor Supply Line module 1 - Circuit Voltage Below Threshold |
| P106C-17 | Sensor Supply Line module 1 - Circuit Voltage Above Threshold |
| P106E-16 | Sensor Supply Line Module 3 - Circuit Voltage Below Threshold |
| P106E-17 | Sensor Supply Line Module 3 - Circuit Voltage Above Threshold |
| P1073-13 | CAN 1 - Circuit Open |
| P1073-88 | CAN 1 - Bus-Off Failure |
| P1080-47 | VCU Function Monitoring - Watchdog/Safety Micro Controller Failure |
| P109F-84 | VCU Temperature Sensor - Signal Below Allowable Range |
| P109F-85 | VCU Temperature Sensor - Signal Above Allowable Range |
| P10B0-00 | Drive Motor Control Module "A" Error Level 1 |
| P10B1-00 | Drive Motor Control Module "A" Error Level 2 |
| P10B2-00 | Drive Motor Control Module "A" Error Level 3 |
| P10B3-00 | Drive Motor Control Module "A" Error Level 4 |
| P10B4-00 | Drive Motor Control Module "A" Error Level 4 & Active Short Circuit |
| P10B5-00 | Drive Motor Control Module "A" Error Level 5 |
| P10B6-00 | Drive Motor Control Module "B" Error Level 1 |
| P10B7-00 | Drive Motor Control Module "B" Error Level 2 |
| P10B8-00 | Drive Motor Control Module "B" Error Level 3 |
| P10B9-00 | Drive Motor Control Module "B" Error Level 4 |
| P10BA-00 | Drive Motor Control Module "A" & "B" - E2E (End-To-End) Testing |
| P10BB-1F | Drive Motor Control Module "A" - Circuit Intermittent |
| P10BB-82 | Drive Motor Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| P10BB-83 | Drive Motor Control Module "A" - Value Of Signal Protection Calculation Incorrect |
| P10BB-84 | Drive Motor Control Module "A" - Signal Below Allowable Range |
| P10BB-85 | Drive Motor Control Module "A" - Signal Above Allowable Range |
| P10BB-86 | Drive Motor Control Module "A" - Signal Invalid |
| P10BB-87 | Drive Motor Control Module "A" - Missing Message |
| P10BC-1F | Drive Motor Control Module "B" - Circuit Intermittent |
| P10BC-82 | Drive Motor Control Module "B" - Alive/Sequence Counter Incorrect/Not Updated |
| P10BC-83 | Drive Motor Control Module "B" - Value Of Signal Protection Calculation Incorrect |
| P10BC-84 | Drive Motor Control Module "B" - Signal Below Allowable Range |
| P10BC-85 | Drive Motor Control Module "B" - Signal Above Allowable Range |
| P10BC-86 | Drive Motor Control Module "B" - Signal Invalid |
| P10BC-87 | Drive Motor Control Module "B" - Missing Message |
| P10BD-00 | Drive Motor Control Module "B" Error Level 4 & Active Short Circuit |
| P10BE-00 | Drive Motor Control Module "B" Error Level 5 |
| P10C0-96 | Electronic Brake Force Distribution (EBD) - Component Internal Failure |
| P10C1-00 | Requested Torque Exceeding Limit IDB |
| P10C3-11 | Hybrid/EV Electronics Coolant Radiation Fan "B" Enable - Circuit Short To Ground |
| P10C3-12 | Hybrid/EV Electronics Coolant Radiation Fan "B" Enable - Circuit Short To Battery |
| P10C3-13 | Hybrid/EV Electronics Coolant Radiation Fan "B" Enable - Circuit Open |
| P10C8-11 | Battery Cooling Pump 1 Enable - Circuit Short To Ground |
| P10C8-12 | Battery Cooling Pump 1 Enable - Circuit Short To Battery |
| P10C8-13 | Battery Cooling Pump 1 Enable - Circuit Open |
| P10C9-11 | Battery Cooling Pump 2 Enable - Circuit Short To Ground |
| P10C9-12 | Battery Cooling Pump 2 Enable - Circuit Short To Battery |
| P10C9-13 | Battery Cooling Pump 2 Enable - Circuit Open |
| P10CB-11 | EDS Cooling Pump Enable - Circuit Short To Ground |
| P10CB-12 | EDS Cooling Pump Enable - Circuit Short To Battery |
| P10CB-13 | EDS Cooling Pump Enable - Circuit Open |
| P10D1-81 | Anti-Lock Brake System (ABS) Control Module "A" - Invalid Serial Data Received |
| P10D1-82 | Anti-Lock Brake System (ABS) Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| P10D1-83 | Anti-Lock Brake System (ABS) Control Module "A" - Value Of Signal Protection Calculation Incorrect |
| P10D1-87 | Anti-Lock Brake System (ABS) Control Module "A"- Missing Message |
| P10D1-96 | IDB - Component Internal Failure |
| P10E1-81 | Automated Driving System Control Module "A" - Invalid Serial Data Received |
| P10E1-87 | Automated Driving System Control Module "A" - Missing Message |
| P10F1-81 | Gateway "A" - Invalid Serial Data Received |
| P10F1-82 | Gateway "A" - Alive/Sequence Counter Incorrect/Not Updated |
| P10F1-83 | Gateway "A" - Value Of Signal Protection Calculation Incorrect |
| P10F1-87 | Gateway "A" - Missing Message |
| P1108-68 | Airbag Control Module Crash Detected - Event Information |
| P1121-81 | Electric Power Steering (EPS) Control Module "A" - Invalid Serial Data Received |
| P1121-82 | Electric Power Steering (EPS) Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| P1121-83 | Electric Power Steering (EPS) Control Module "A" - Value Of Signal Protection Calculation Incorrect |
| P1121-87 | Electric Power Steering (EPS) Control Module "A" - Missing Message |
| P1130-00 | Drive Motor Control Module 'B" - E2E (End-To-End) Testing & Rear Motor Torque Invalid |
| P1131-00 | IDB Component - E2E (End-To-End) Testing & Vehicle Speed Invalid |
| P1132-00 | Proximity Pilot Signal Voltage |
| P1133-64 | Throttle/Pedal Position Sensor/Switch A/B Safety - Signal Plausibility Failure |
| P1134-00 | Park Lock Request Comparison |
| P1135-00 | Active BMS Failure Confirmed Error |
| P1136-00 | Active BMS Failure Confirmed Error During Charging |
| P1137-00 | Active BMS High Error Level Confirmed Error |
| P1138-00 | Park Request Error During Charging |
| P1139-00 | Drive Motor Control Module "B" Discharge Request Comparison Error |
| P113A-00 | Fast Charge Disable Request Comparison Error |
| P113B-00 | 12V Power Supply In Functional Range Error |
| P133C-00 | 12V Power Supply Out Of Range Error |
| P113D-00 | Park Lock Engagement Request After Crash |
| P113E-00 | High Request Torque Change Rate Comparison Confirmed Error |
| P113F-00 | High Actual Torque Change Rate Comparison Confirmed Error |
| P1140-00 | Unintended Movement Actual Torque Request Comparison Confirmed Error |
| P1141-81 | Airbag Control Module (ACM) - Invalid Serial Data Received |
| P1141-87 | Airbag Control Module (ACM) - Missing Message |
| P1151-29 | Gear Shifter Module - Signal Invalid |
| P1151-81 | Gear Shifter Module - Invalid Serial Data Received |
| P1151-82 | Gear Shifter Module - Alive/Sequence Counter Incorrect/Not Updated |
| P1151-83 | Gear Shifter Module - Value Of Signal Protection Calculation Incorrect |
| P1051-87 | Gear Shifter Module - Missing Message |
| P1A00-00 | DC/DC Converter Control Module "A" Error Level 1 |
| P1A01-00 | DC/DC Converter Control Module "A" Error Level 2 |
| P1A02-00 | DC/DC Converter Control Module "A" Error Level 3 |
| P1A03-00 | DC/DC Converter Control Module "A" Error Level 4 |
| P1A04-00 | DC/DC Converter Control Module "A" Error Level 5 |
| P1A05-61 | DC/DC Converter Control Module "A" - Signal Calculation Failure |
| P1A05-62 | DC/DC Converter Control Module "A" - Signal Compare Failure |
| P1A05-81 | DC/DC Converter Control Module "A" - Invalid Serial Data Received |
| P1A05-82 | DC/DC Converter Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| P1A05-83 | DC/DC Converter Control Module "A"- Value Of Signal Protection Calculation Incorrect |
| P1A05-87 | DC/DC Converter Control Module "A" - Missing Message |
| P1A11-00 | Battery Energy Control Module "A" Error Level 2 |
| P1A12-00 | Battery Energy Control Module "A" Error Level 3, 4 |
| P1A13-00 | Battery Energy Control Module "A" Error Level 5 |
| P1D67-17 | Battery Charger Control Module "A" - Circuit Voltage Above Threshold |
| P1D67-61 | Battery Charger Control Module "A" - Signal Calculation Failure |
| P1D67-62 | Battery Charger Control Module "A" - Signal Compare Failure |
| P1D67-81 | Battery Energy Control Module "A" - Invalid Serial Data Received |
| P1D67-82 | Battery Energy Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| P1D67-83 | Battery Charger Control Module "A" - Value Of Signal Protection Calculation Incorrect |
| P1D67-87 | Battery Charger Control Module "A" - Missing Message |
| P1D68-00 | Battery Charger Control Module "A" Error Level 1 |
| P1D69-00 | Battery Charger Control Module "A" Error Level 2 |
| P1D6A-00 | Battery Charger Control Module "A" Error Level 3 |
| P1D6B-00 | Battery Charger Control Module "A" Error Level 4 |
| P1D6C-00 | Battery Charger Control Module "A" Error Level 5 |
| P2135-29 | Throttle/Pedal Position Sensor/Switch A/B - Signal Invalid |
| P2135-64 | Throttle/Pedal Position Sensor/Switch A/B - Signal Plausibility Failure |
| P2299-64 | Accelerator Pedal Position/Brake Pedal Position - Signal Plausibility Failure |
| P2544-64 | IDB Torque Intervention - Signal Plausibility Failure |
| C05CA-86 | Brake Master Cylinder Pressure - Signal Invalid |
| U0001-13 | BA CAN - Circuit Open |
| U0001-88 | BA CAN - Bus-Off Failure |
| U1171-13 | Chassis CAN - Circuit Open |
| U1171-88 | Chassis CAN - Bus-Off Failure |
| U1172-13 | Powertrain CAN - Circuit Open |
| U1172-88 | Powertrain CAN - Bus-Off Failure |
| U12A1-88 | LIN1 - Bus Off |
| U0412-82 | Invalid Data Received From Battery Energy Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| U0412-83 | Invalid Data Received From Battery Energy Control Module "A" - Value Of Signal Protection Calculation Incorrect |
| U0447-81 | Invalid Data Received From Gateway "A" - Invalid Serial Data Received |
| U0447-82 | Invalid Data Received From Gateway "A" - Alive/Sequence Counter Incorrect/Not Updated |
| U0447-83 | Invalid Data Received From Gateway "A" - Value Of Signal Protection Calculation Incorrect |
| U160E-82 | Invalid Data Received From IDB - Alive/Sequence Counter Incorrect/Not Updated |
| U160E-83 | Invalid Data Received From IDB - Value Of Signal Protection Calculation Incorrect |
| P10F1-87 | Lost Communication With Gateway "A" - Missing Message |
| U0452-82 | Invalid Data Received From ACM - Alive/Sequence Counter Incorrect/Not Updated |
| U0452-83 | Invalid Data Received From ACM - Value Of Signal Protection Calculation Incorrect |
| U0411-81 | Invalid Data Received From Drive Motor Control Module "A" - Invalid Serial Data Received |
| U0452-81 | Invalid Data Received From ACM - Invalid Serial Data Received |
| U0593-81 | Invalid Data Received From Drive Motor Control Module "B" - Signal Invalid |
| U0411-82 | Invalid Data Received From Drive Motor Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| U0411-83 | Invalid Data Received From Drive Motor Control Module "A" - Value Of Signal Protection Calculation Incorrect |
| U0593-82 | Invalid Data Received From Drive Motor Control Module "B" - Alive/Sequence Counter Incorrect/Not Updated |
| U0593-83 | Invalid Data Received From Drive Motor Control Module "B" - Value Of Signal Protection Calculation Incorrect |
| U0420-81 | Invalid Data Received From Electric Power Steering (EPS) Control Module "A" - Invalid Serial Data Received |
| U0420-82 | Invalid Data Received From Electric Power Steering (EPS) Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| U0420-83 | Invalid Data Received From Electric Power Steering (EPS) Control Module "A" - Value Of Signal Protection Calculation Incorrect |
| U160E-81 | Invalid Data Received From IDB - Invalid Serial Data Received |
| P0531-11 | A/C Refrigerant Pressure Sensor "A" Circuit Range/Performance - Circuit Short To Ground |
| P0531-12 | A/C Refrigerant Pressure Sensor "A" Circuit Range/Performance - Circuit Short To Ground |
| P1141-01 | Charge Port Door "A" Illumination Light - General Electric Failure |
| P1142-00 | EDS Minor Fault Confirmed Error |
| P1143-00 | Active HVIL Error Confirmed Error During High Speed Condition |
| P1144-00 | OBC Fault Status Confirmed Error During High Speed Condition |
| P1145-00 | Invalid Brake Pedal Status |
| P1146-00 | DCDC Fault Status Confirmed Error During Low Speed Condition |
| P1147-00 | Active HVIL Error Confirmed Error During Low Speed Condition |
| P1148-00 | FC Contactor Status Confirmed Error |
| P1149-00 | Active Isolation Error Confirmed Error |
| P1150-00 | Active BMS Isolation Confirmed Error During High Speed Condition |
| P1151-00 | Rear Motor Torque Disable Request During Normal Or Emergency Shut Down |
| P1152-00 | Charge Lock Status Confirmed Error |
| P1153-00 | Charge Lock Request Confirmed Error |
| P1154-00 | Front Motor Discharge Request |
| P1155-00 | Rear Motor Discharge Request |
| P1156-00 | BMS Failure During Drive |
| P1157-00 | DCDC Fault Status Confirmed Error During High Speed Condition |
| P1158-00 | Hybrid/EV Battery Voltage System High-Voltage Interlock Loop (HVIL) |
| P00B1-11 | Radiator Coolant Temperature Sensor - Circuit Short To Ground |
| P00B1-12 | Radiator Coolant Temperature Sensor - Circuit Short To Battery |
| P00B1-1F | Radiator Coolant Temperature Sensor - Circuit Intermittent |
| P0531-1F | A/C Refrigerant Pressure Sensor "A" Circuit Range/Performance - Circuit Intermittent |
| P0A17-29 | Motor Torque Sensor Circuit - Signal Invalid |
| P0A1F-00 | Battery Energy Control Module "A" - E2E (End-To-End) Testing |
| P0A81-11 | Hybrid/EV Battery Pack Cooling Fan 1 Control - Circuit Short To Ground |
| P0A81-12 | Hybrid/EV Battery Pack Cooling Fan 1 Control - Circuit Short To Battery |
| P0A81-13 | Hybrid/EV Battery Pack Cooling Fan 1 Control - Circuit Open |
| P0CFF-04 | Hybrid/EV Battery Pack Coolant Pump "A" - System Internal Failures |
| P0CFF-07 | Hybrid/EV Battery Pack Coolant Pump "A" - Mechanical Failure |
| P0CFF-09 | Hybrid/EV Battery Pack Coolant Pump "A" - Component Failure |
| P0CFF-11 | Hybrid/EV Battery Pack Coolant Pump "A" - Circuit Short To Ground |
| P0CFF-12 | Hybrid/EV Battery Pack Coolant Pump "A" - Circuit Short To Battery |
| P0CFF-13 | Hybrid/EV Battery Pack Coolant Pump "A" - Circuit Open |
| P0CFF-19 | Hybrid/EV Battery Pack Coolant Pump "A" - Circuit Current Above Threshold |
| P0CFF-86 | Hybrid/EV Battery Pack Coolant Pump "A" - Signal Invalid |
| P0CFF-94 | Hybrid/EV Battery Pack Coolant Pump "A" - Unexpected Operation |
| P0CFF-98 | Hybrid/EV Battery Pack Coolant Pump "A" - Component Or System Over Temperature |
| P0D99-98 | Battery Charger Coupler Temperature sensor "A" - Component Or System Over Temperature |
| P0E5F-08 | Battery Charger Coupler Temperature "A" Too High - Bus Signal/Message Failure |
| P0E88-18 | Battery charger "B" Input Current Too Low - Circuit Current Below Threshold |
| P101E-1C | Cabin Heater "A" - Circuit Voltage Out Of Range |
| P10CC-11 | EDS Cooling Pump 2 Enable - Circuit Short To Ground |
| P10CC-12 | EDS Cooling Pump 2 Enable - Circuit Short To Battery |
| P10CC-13 | EDS Cooling Pump 2 Enable - Circuit Open |
| P114A-00 | EDS Critical Fault Confirmed Error |
| P114B-00 | Active HVIL Error Confirmed Error During Stationary Condition |
| P114C-00 | Active HVIL Error Confirmed Error During Charging |
| P114D-00 | OBC Fault Status Confirmed Error During Low Speed Condition |
| P114F-00 | Active BMS Isolation Confirmed Error During Low Speed Condition |
| U0121-87 | Lost Communication With Automated Driving System Control Module "A" - Missing Message |
| U019B-87 | Lost Communication With Battery Charger Control Module "A" - Missing Message |
| U0298-87 | Lost Communication With DC/DC Converter Control Module "A" - Missing Message |
| U0411-87 | Lost Communication With Drive Motor Control Module "A" - Missing Message |
| U0412-81 | Invalid Data Received From Battery Energy Control Module "A" - Invalid Serial Data Received |
| U0461-81 | Invalid Data Received From Acoustic Vehicle Alerting System (AVAS) Control Module "A" - Invalid Serial Data Received |
| U049C-62 | Invalid Data Received From Battery Charger Control Module "A" - Signal Compare Failure |
| U049C-81 | Invalid Data Received From Battery Charger Control Module "A" - Invalid Serial Data Received |
| U049C-82 | Invalid Data Received From Battery Charger Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| U049C-83 | Invalid Data Received From Battery Charger Control Module "A" - Value of Signal Protection Calculation Incorrect |
| U049F-29 | Invalid Data Received From Gear Shifter Module - Signal Invalid |
| U049F-81 | Invalid Data Received From Gear Shifter Module - Invalid Serial Data Received |
| U049F-82 | Invalid Data Received From Gear Shifter Module - Alive/Sequence Counter Incorrect/Not Updated |
| U049F-83 | Invalid Data Received From Gear Shifter Module - Value Of Signal Protection Calculation Incorrect |
| U0599-62 | Invalid Data Received From DC/DC Converter Control Module "A" - Signal Compare Failure |
| U0599-81 | Invalid Data Received From DC/DC Converter Control Module "A" - Invalid Serial Data Received |
| U0599-82 | Invalid Data Received From DC/DC Converter Control Module "A" - Alive/Sequence Counter Incorrect/Not Updated |
| U0599-83 | Invalid Data Received From DC/DC Converter Control Module "A" - Value Of Signal Protection Calculation Incorrect |
| U0910-00 | Drive Motor Control Module "A" Error Level 1 |
| U0911-00 | Drive Motor Control Module "A" Error Level 2 |
| U0912-00 | Drive Motor Control Module "A" Error Level 3 |
| P10B3-00 | Drive Motor Control Module "A" Error Level 4 |
| U0914-00 | Drive Motor Control Module "A" Error Level 4 & Active Short Circuit |
| U0915-00 | Drive Motor Control Module "A" Error Level 5 |
| U0916-00 | Drive Motor Control Module "B" Error Level 1 |
| U0917-00 | Drive Motor Control Module "B" Error Level 2 |
| U0918-00 | Drive Motor Control Module "B" Error Level 3 |
| U0919-00 | Drive Motor Control Module "B" Error Level 4 |
| U091A-00 | Drive Motor Control Module "B" Error Level 4 & Active Short Circuit |
| U091B-00 | Drive Motor Control Module "B" Error Level 5 |
| U091C-00 | DC/DC Converter Control Module "A" Error Level 1 |
| U091D-00 | DC/DC Converter Control Module "A" Error Level 2 |
| U091E-00 | DC/DC Converter Control Module "A" Error Level 3 |
| U091F-00 | DC/DC Converter Control Module "A" Error Level 4 |
| U0920-00 | DC/DC Converter Control Module "A" Error Level 5 |
| U0921-00 | Battery Energy Control Module "A" Error Level 2 |
| U0922-00 | Battery Energy Control Module "A" Error Level 3, 4 |
| U0923-00 | Battery Energy Control Module "A" Error Level 5 |
| U0924-00 | Battery Charger Control Module "A" Error Level 1 |
| U0925-00 | Battery Charger Control Module "A" Error Level 2 |
| U0926-00 | Battery Charger Control Module "A" Error Level 3 |
| U0927-00 | Battery Charger Control Module "A" Error Level 4 |
| U0928-00 | Battery Charger Control Module "A" Error Level 5 |
| U0929-00 | DCFC Error Level 1 |
| U092A-00 | DCFC Error Level 2 |
| U092B-00 | DCFC Error Level 3 |
| U1252-81 | Invalid Data Received From A/C Compressor "A"/"B" - Invalid Serial Data Received |
| U1252-87 | Lost Communication With A/C Compressor "A"/"B"- Missing Message |
| U1253-81 | Invalid Data Received From Cabin Heater "A" - Invalid Serial Data Received |
| U1253-87 | Lost Communication With Cabin Heater A - Missing Message |
| U1254-16 | Invalid Data Received From Multiway Valve "A" - Circuit Voltage Below Threshold |
| U1254-17 | Invalid Data Received From Multiway Valve "A" - Circuit Voltage Above Threshold |
| U1254-81 | Invalid Data Received From Multiway Valve "A" - Invalid Serial Data Received |
| U1254-87 | Lost Communication With Multiway Valve "A" - Missing Message |
| U1254-96 | Invalid Data Received From Multiway Valve "A" - Component Internal Failure |
| U1254-98 | Invalid Data Received From Multiway Valve "A" - Component Or System Over Temperature |
| U1255-01 | Invalid Data Received From Active Grill Shutter "A" Control Module - General Electric Failure |
| U1255-07 | Invalid Data Received From Active Grill Shutter "A" Control Module - Mechanical Failure |
| U1255-16 | Invalid Data Received From Active Grill Shutter "A" Control Module - Circuit Voltage Below Threshold |
| U1255-17 | Invalid Data Received From Active Grill Shutter "A" Control Module - Circuit Voltage Above Threshold |
| U1255-54 | Invalid Data Received From Active Grill Shutter "A" Control Module - Missing Calibration |
| U1255-81 | Invalid Data Received From Active Grill Shutter "A" Control Module - Invalid Serial Data Received |
| U1255-87 | Lost Communication With Active Grill Shutter "A" Control Module - Missing Message |
| U1255-97 | Invalid Data Received From Active Grill Shutter "A" Control Module - Component Or System Operation Obstructed Or Blocked |
| U1255-98 | Invalid Data Received From Active Grill Shutter "A" Control Module - Component Or System Over Temperature |
| U1256-16 | Invalid Data Received From Multiway Valve "B" - Circuit Voltage Below Threshold |
| U1256-17 | Invalid Data Received From Multiway Valve "B" - Circuit Voltage Above Threshold |
| U1256-81 | Invalid Data Received From Multiway Valve "B" - Invalid Serial Data Received |
| U1256-87 | Lost Communication With Multiway Valve "B" - Missing Message |
| U1256-96 | Invalid Data Received From Multiway Valve "B" - Component Internal Failure |
| U1256-98 | Invalid Data Received From Multiway Valve "B" - Component Or System Over Temperature |
| U160E-29 | Invalid Data Received From IDB - Signal Invalid |
| U160E-64 | Invalid Data Received From IDB - Signal Plausibility Failure |
| U3002-56 | Vehicle Identification Number - Invalid/Incompatible Configuration |
| U019E-87 | Lost Communication With Gear Shifter Module - Missing Message |
| U1108-87 | Lost Communication With ACM - Missing Message |
| U0292-87 | Lost Communication With Drive Motor Control Module "B" - Missing Message |
| U0131-87 | Lost Communication With Electric Power Steering (EPS) Control Module "A" - Missing Message |
| U0415-81 | Invalid Data Received From Automated Driving System Control Module "A" - Invalid Serial Data Received |
| U0111-87 | Lost Communication With Battery Energy Control Module "A" - Missing Message |
| U0160-87 | Lost Communication With Acoustic Vehicle Alerting System (AVAS) Control Module "A"- Missing Message |
| P114E-00 | OBC Fault Status Confirmed Error During Charging |
| P113C-00 | 12V Power Supply Out Of Range Error |
| U110E-87 | Lost Communication With IDB - Missing Message |