Alternative Hall Sending Unit Operation Check
- Disconnect high tension wire at distributor and connect it to ground. Connect a test light (4-24V) between terminal 1 and 15 of ignition coil. Crank engine with starter for approximately 5 seconds.
- Test light must flicker. If not, replace Hall sending unit in distributor.