INTERMITTENT ELECTRICAL PROBLEMS - CHECK GROUND WIRE

INTERMITTENT ELECTRICAL PROBLEMS - CHECK GROUND WIRE

TECHNICAL INFORMATION TIP

Reference Number(s): VLK0002AP, Date of Issue:  August 1988

INTERMITTENT RABBIT/GOLF GROUND CONNECTION

YEAR(S): 1983-84

MANUFACTURER: Volkswagen

MODELS: Rabbit

DATE OF ISSUE: August 1988

ISSUE

Some 1983-84 Volkswagen Rabbits may have intermittent electrical troubles such as no-starts, erratic dash gauge readings, etc. When you are troubleshooting these problems, always check the engine/ transmission mount under the battery. The battery ground is bolted to this mount under the battery. The mount's through-bolts can work themselves loose and cause an intermittent ground connection. Be sure this connection is clean and tight.

Courtesy of Import Service Magazine

with thanks to:

Douglas M. Colbary

D.C.R.

Eastlake, OH 44094

REFERENCE NUMBER

VLK0002AP

NOTE: This information has been obtained from sources generally believed to be reliable. Use your own judgment before relying on this data. Neither the suppliers of these Technical Information Tips, nor lemon-25 Repair Information Company, LLC, guarantees or assumes responsibility for data accuracy or completeness, nor is liability assumed by the suppliers of these Technical Information Tips or lemon-25 Repair Information Company, LLC, for any claims or damages resulting from the use of this information.