Transfer Pump Delivery Volume
- Check voltage supply to pumps. Connect Jumper Switch (US 4480/3 ) in place of fuel pump relay, on relay panel. Remove fuel filler cap. Disconnect and plug off Black fuel line from sending unit.
- Connect hose to sender port and place opposite end in measuring container. Turn on fuel pumps. Minimum transfer pump delivery volume should be .42 qts. (.4L) in 10 seconds. Reconnect fuel line to sender.