Freeze Protection, Checking And Adding Coolant Additive If Necessary
Special tools and workshop equipment required
- Refractometer :T10007A
- Refractometer :T10007B
The cut-off line can be read to obtain an accurate reading for the following tests. Place a drop of water on the glass using a pipette to improve the readability of the cut-off line. The cut-off line is now clearly recognizable on the "WATERLINE".
-- Check the coolant additive concentration using the Refractometer (observe the operating instructions).
The scale -1- on the refractometer refers to the G12++ and G12evo coolant additives.
The scale -2- on the refractometer refers to the G13 coolant additive.
-- Drain some of the coolant and add coolant additive if the freeze protection is inadequate. Refer to COOLANT LEVEL, CHECKING AND FILLING IF NECESSARY .
If it cannot clearly determined which coolant additive is in the coolant system, use the scale -2- for coolant additive G13.
Please follow all waste disposal regulations!
-- Check the concentration of the coolant additive again after the road test.