When throttle is closed suddenly, carburetor air is shut off instantly but fuel flows momentarily which results in a rich mixture. To eliminate backfire, anti-backfire valve opens momentarily to allow air from air pump to enter intake manifold and lean mixture. Opening of valve is triggered whenever there is a rapid rise in intake manifold vacuum. Opening of this valve also prevents rapid reduction of engine RPM which assists in eliminating the need of a dashpot.

Fig 1: Typical Air Injection System
G09312956Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Fig 2: Air Pump (With External Relief Valve)
G09312957Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Fig 3: Anti Backfire Valve (Typical)
G09312958Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002