BOSCH Electronic Ignition System: Overhaul: Inspection
Springs for weights must not be deformed or damaged. Holes in centrifugal governor weights must not be oval or deformed. Distributor shaft-to-cam clearance should not exceed 0.004" (.1 mm). Distributor shaft-to-housing clearance should not exceed 0.008" (.2 mm).